813443
17
Zoom out
Zoom in
Previous page
1/32
Next page
BK740 Page 17
Ecoburn (S3) Stove User Guide
6.6 Smoke Control Area (The Clean Air Act 1993 & Smoke Control Areas)
If the stove is to be installed in a designated Smoke Control Area (further information can
be found via https://www.gov.uk/smoke-control-area-rules ) then the installer will have
fitted the restrictor plate for the secondary air lever, to prevent total closure of this air
control.
NOTE :
The minimum air control setting is governed in manufacture to meet the
requirements of Smoke Control exemption and as a result the appliance will NOT
shut down completely when in the minimum air position setting.
Removal or modification of the fitted air control plate (See Fig. 5) is illegal when the
appliance is installed in a smoke exemption area and doing so may result in
prosecution and fine.
6.7 Typical burn for nominal output
To perform the most efficient burn at the nominal rated output please consult the
specification table at the rear of this manual. Please note, many factors can affect the
nominal output, so the stated weights of fuel (Seasoned hard wood, Beech and Mineral
solid fuel, Maxibrite’) are a guide, which is a representation to laboratory test burn
conditions.
Restrictor Plate
(Smoke Exemption)
Secondary
Air Control
Fig. 5. Fitted Smoke Exemption Restrictor Plate
Security
Screw Fixing
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Ecoburn at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Ecoburn in the language / languages: English as an attachment in your email.

The manual is 1.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info