474157
12
Zoom out
Zoom in
Previous page
1/60
Next page
11
Settings
1 Close door
2 Teach radio channel 2
- Teach button 2 of the remote control on radio channel 2 of the radio
receiver (see under R)
3 set DIP switch 2 to position “ON”: Adapt function mode of the safety
connection
- only if 2 press buttons are attached, otherwise the safety connection
(terminal 1 + 2) e.g. for a light barrier can be used.
4 Put DIP switch 8 in position “ON” (activates partial opening)
Action
Press key 2 of the hand transmitter or press button 2 (open door from
“CLOSED” end position).
- Door open until key 2 of the hand transmitter or press button 2 is
pressed a second time, or the door has reached the “DOOR OPEN”
position.
Press key 2 of the hand transmitter or the press button 2 on reaching
the desired position.
Close door with key 2 of the hand transmitter or press button 2.
The desired partial opening is now stored and can be directly activated
with button 2 of the remote control or wall switch 2.
To cancel the partial opening, set DIP switch 8 to the “OFF” position.
2 CHANNEL OPERATION (DEFINED OPENING AND CLOSING)
Press button 1/radio channel 1 opens and press button 2/radio channel 2
closes the door.
2-channel operation can also be used only with wall switch or remote con-
trol. If 2 channel operation is only controlled via the hand transmitter, the
safety connection is also available.
Settings
1 Set DIP switch 2 to “ON” position if only wall switch 2 is connected.
2 Put DIP switch 7 in Position “ON”
3 Put DIP switch 8 in Position “OFF”
4 Teach the second key of the hand transmitter on radio channel 2.
DOOR STATUS INDICATION
If a warning light is attached, this indicates whether the door is closed or
opened. The warning light shines, if the door is not “CLOSED”.
Settings
1 Set DIP switch 4 in Position “ON”
2 Connect warning light 24 V to terminals 5 + 6 (see above).
ADDITIONAL INFORMATION
1 LED (29) shows the condition of the control unit. If the LED flashes, no
power value has been taught. In normal operation, LED (29) behaves in
the same way as a connected warning light.
2 Wire bridge (31): if the drive mechanism is to be operated without soft
running, the wire bridge can be cut. Soft running is then deactivated.
Alternative: Use of a TorMinal, see U.
U
TORMINAL INTERFACE (32)
APERTO 868 L and APERTO 868 LX only
Control programmer for individual programming of the L control unit.
For further information, see TorMinal user instructions.
IV. CARE AND MAINTENANCE
Chains and tracks that become very dirty should be cleaned with a
clean cloth.
Lubricate the chain once a year with chain lubricant e.g. WD 40.
Check that all screws and bolts are tightened. Tighten, additionally,
where necessary.
Check safety devices for correct operation regularly, but at least once a
year.
Check the door according to manufacturer‘s instructions, but at least
once a year.
Check regularly:
a) Disconnection. Stop hinged double door during opening and closing.
The door must stop if it encounters slight resistance.
b) Emergency unlocking device: door must be easy to unlock by hand.
c) Light barrier, if present: open/close door and interrupt light barrier.
Proceed as set on DIP switch.
DISASSEMBLY
The sequence of operations is identical to that described in the Section
entitled „Installation“ but in reverse order.
The setting procedures described are not applicable.
WARRANTY AND AFTER-SALES SERVICE
If you require after-sales service, spare parts or accessories, please
contact your specialist retailer.
Important: - In the event the main cable to the 800 N tractive force drive
becomes damaged, the equipment should be sent to the manufacturer
(the main cable is not replaceable).
Thank you for buying an Aperto unit. We are sure you will enjoy many ye-
ars of reliable service.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aperto 868 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aperto 868 in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Spanish as an attachment in your email.

The manual is 1,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aperto 868

Aperto 868 Additional guide - Dutch - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info