541415
88
Zoom out
Zoom in
Previous page
1/114
Next page
TFTP
76
TFTP To CIB Configuration Data Requirements
The following information lists the configuration field and the required
character string that precedes the user configuration value that has been
chosen. Each configuration field data text string entry must be separated
from the previous and the following by new line character sequence, i.e.,
carriage return (0x0D hex) or carriage return/linefeed (0x0D 0x0A hex)
character combination. Without this delineation, the configuration of the
fields will not occur. The general format of these configuration field strings is:
FIELD IDENTIFIER = VALUE
Where FIELD IDENTIFIER is specified to the left of the = (or: which is also
allowed) followed by the VALUE.
For example, if you wanted to change the baud rate to 9600:
BAUD = 9600
Text strings must be surrounded by double quotes! If the parameter is multi-
optional (multiple ports, for example), = must be followed by a designating
number, then a value.
For example if you want port 7 to be designated ‘computer room’ then:
PORT NAME = 7 “COMPUTER ROOM”
BAUD = 9600
If the FIELD is multi-dimensional such as PORT_NAME (which has up to 16
ports), the designating number followed by “=” and then the value.
For example:
PORT NAME [1] = “Port Number 1”
or
ELAN NAME [2] = “Elan Two”
One, or all, configuration fields can be used in a TFTP configuration file for
downloading purposes. When a given configuration file is not to be
downloaded, the default or previously entered configuration data for that field
will remain active.
Text strings require the double quote (“”) character. When a character string
is to be removed, enter a NULL STRING. A NULL STRING is defined as
two consecutive double quotes (“”) which will be interpreted as a string
length of zero.
In the configuration field examples that follow, there are numerous fields that
do not have double quotes around the value that is to be entered. These are
“defined” as constant fields. The allowable constant values are listed for each
field. The use of quotes around the constant value will cause this field setting
to be ignored.
88


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allied Telesis AT-S7 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allied Telesis AT-S7 in the language / languages: English as an attachment in your email.

The manual is 1,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info