44 ML3000 User Guide
Archiving the Console Settings
The console settings can be saved to an external
device such as a MIDI sequencer or data archiver
using the dump out facility. Settings can be loaded
back into the console using dump in. This is ideal
when you want to archive the settings to use at a
later date, for example a re-run of a previous
performance. You can also use the dump facility to
program additional ML3000 consoles, for example
when setting up duplicate shows or swapping
consoles around. Simply link MIDI OUT from one to
MIDI IN of the other and action the dump out facility.
Settings which are archived :
9 Current mute settings
9 Current Mute group assignments
9 Current VCA group assignments
9 All snapshot memories
Settings which are not archived :
8 Current console operating mode
MIDI Dump Out
Connect the console to a suitable MIDI archiving
device. Set the same MIDI channel number on
both. Check the rear switch is set to MIDI. Press
the MIDI and VIEW keys together. The console
dumps the current settings and memory contents
using a SysEx message string. During this time the
MIDI LED lights to show that data is being sent via
the MIDI port. Note that this operation can take up
to 10 seconds during which time the console mutes
and assignment operations are interrupted.
MIDI Dump In
Connect the console to the MIDI archiving device.
Set the same MIDI channel number on both. Check
the rear switch is set to MIDI. Start the process
using the MIDI archiver. The console current
settings and memory contents are overwritten.
During this time the MIDI LED lights to show that
data is being received by the console. Note that this
operation can take a while during which time the
console mute and assignment operations are
interrupted.
If you are using a MIDI sequencer to record the
dump out data string then make sure you play it
back at the same speed you recorded it. If you
dump it back into the console faster than it was
recorded some data may not load correctly.
MIDI Dump Message Format
The format for dump out and in is identical. The
dump data string is made up of multiple System
Exclusive messages (known as packets) which
contain the console information.
Transmit and Receive. The format for a single
packet is as follows:
F0 <SysEx header> <packet type> <packet
number> <data> <checksum> F7
<SysEx header> = 00 00 1A 50 07 VV vv nn
Where VV = software version number – major
vv = software version number – minor
nn = console MIDI channel number
<packet no.> = packet number from 0 to 127
<data> = block of console data (7-bit format)
<checksum> = checksum to allow error detection
MIDI Dump Errors
If the console or connected equipment fails to
respond to a MIDI dump then check:
The MIDI cable is good and correctly plugged
The correct MIDI channel number is selected
The console rear panel switch is set to MIDI
Try again
Allen & Heath ML Archiver
The ML Archiver Windows™ utility for the PC can
be downloaded from the Allen & Heath Internet site.
This can be used to archive data to and from the
PC via MIDI or RS232.
The program also includes the useful Snapshot
Manager which lets you store and recall the console
mute settings and VCA group assignments from the
128 internal snapshot memories. The snapshots
cannot be accessed from the console control panel
itself. The archiver provides this extra feature.
Check the Allen & Heath Web site for further details
and loading instructions.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath ML 3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath ML 3000 in the language / languages: English as an attachment in your email.

The manual is 3,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info