10 minutes the concentration is still above 200PPM the alarm will be activated again. During the hush
function, press the test button to immediately disable the hush function and make the alarm audible.
LED INDICATION:
Red LED Alarm, carbon monoxide present
Yellow LED Sensor problem
Green LED Normal functioning, the LED ashesevery45seconds
BATTERY INFORMATION INDICATION:
1. Every 45 seconds the battery is automatically checked.
2. Every45secondsthegreenLEDwilllightupbrieyaslongasthetotalbatteryvoltageisabove3,6
Volt. This means that the battery capacity is okay. If the battery voltage drops below 3.6 Volts, the
yellow“Fault”1xLEDwillbrieylightuponceaminuteandaone-timebeepwillsound.Nowthe
batteries should be replaced as soon as possible.
Use High Energy Alkaline batteries (3 x LR6 / 1,5V AA). Rechargeable batteries are not suitable. The
supplied batteries will last approximately 24 months before they run out
REASON FOR SENSOR FAULT:
Faults can be caused by broken circuitry, a faulty sensor or faulty electronic parts.
SENSOR FAULT CAUSED BY CHEMICAL GASES:
When volatile chemical gases such as alcohol are the cause for error detection, this may be corrected by
switching the detector off and leave it in fresh air for 24 hours. This will restore the sensor. If the error is
not cleared after these 24 hours, the detector is faulty and should be replaced. Don’t repair the detector
yourself, but have it repaired by the importer.
When the alarm is contaminated and damaged by high concentrations of chemical gases, the sensor could
be affected. This will lead to a temporary error or permanent damage. When the alarm sounds and you
can smell a chemical gas, this could be the reason. Carbon monoxide is a colourless and odourless gas.
Chemical gases do have an odour.
The following substances and gases can cause false alarms or permanently damage the detector:
Methane, propane, iso-butane, ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, acid, ether,
hydrogen, hepatic gas, sulphur dioxide, aerosol, propellant, alcohol preparation, paint, thinner, dissolvent,
bonding agents, shampoo, aftershave balm, perfume, car exhaust (cold start) and certain cleaning agents.
MAINTENACE:
To keep your CO detector in proper working order, please follow these easy steps:
Once a month, check that the alarm is working properly by pressing the test button.
Clean the CO detector with a vacuum cleaner or with a soft cloth or brush once every month to remove
excess dust.
Check whether the batteries are damaged, exhausted or corroded.
Explain to children that they should not play with the CO detector.
Ensure children are aware of the dangers of carbon monoxide poisoning.
Never use cleaning agents or other solutions to clean the CO detector.
Never use air fresheners, hair spray or other aerosols near the CO detector.
Don’t paint the CO detector. Paint covers the vents preventing the sensor from detecting CO.
Never disassemble, repair or modify the product yourself; there’s a high risk that it will no longer
function correctly or reliably.
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alecto SCA04 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alecto SCA04 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info