INSTALLATION:
1. Insert the included batteries into the detector.
A. Turn the securing pins inward
B. Insert the 3 AA batteries, observing polarity.
(High Energy Alkaline batteries 1.5V AA - LR6)
C. The power, fault and alarm LEDs will light up for 0.5 seconds and
the detector will emit a short audible signal.
2. Push the latch out of the mounting plate.
3. Install the mounting plate on a suitable spot
4. Use the included plugs and screws.
5. Youcanperformthersttestbybrieypressingthetestbutton,
see also paragraph “Testing”.
6. Now interlock the mounting plate with the CO detector by inserting the
latch on top into the hole until you hear a click.
7. The CO detector is now functional.
USE:
1. Every45seconds,thepowerLEDlightsbrieytoindicatethatthedetectorisoperating.
2. Whenthedetectorgivesashortbleepevery60secondsandtheyellow“Fault”LEDashes,the
batteries should be replaced as soon as possible. At the start of these warnings, the detector will
operate for 30 days standby or 4 minutes in alarm mode.
3. The table below shows when the detector will sound the alarm.
CO concentration NO ALARM
for
ALARM
for
30PPM 120 min. -
50PPM 60 min. 90 min.
100PPM 10 min. 40 min.
300PPM - 3 min.
In accordance to the EN50291 standard.
4. When the alarm sounds, it will turn off within 6 seconds after moving the detector to a space with a CO
concentration below 40PPM.
5. The alarm sound can be turned off for up to 10 minutes by pressing and holding the TEST button for 3
seconds (<200PPM).
6. The detector will automatically perform a fault inspection every 180 seconds.
TESTING:
When the CO detector is operating under normal conditions, the sensor and siren should be tested at least
every month. Press the “TEST” key. “POWER”, “FAULT” and “ALARM” LED light up. Then the detector
gives 5 beeps within 10 seconds and also the red “ALARM” LED lights up. Everything is now ok.
If the detector gives an error message, the yellow “FAULT” LED will light 2 times and give 2 beeps per
minute.
SILENCING ALARM (HUSH FUNCTION):
Sometimesthealarmmaygooffduetoinuenceofenvironmentalfactors.Forexample,smokecontaining
certain concentrations of carbon monoxide or other chemical gases. When the CO level is lower than
200PPM, you can press the “TEST” button. The alarm will stop and the detector will immediately check the
CO value again. When the concentration is higher than 200PPM it is impossible to stop the alarm.
The red LED will blink 8 times per second- and the sound signal will stop for max 10 minutes. If after max
- AA +
+ AA -
- AA +
2.
6.
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alecto SCA04 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alecto SCA04 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info