The SA-240 is a smoke detector set for discovery of fire in the first stage. If smoke develops, the SA-240 will
give a loud beep of at least 85dB (A). As part of the link function all the smoke alarms within range will sound
the alarm. We advice to test the smoke detectors weekly using the test button on the detectors. Save this
manual in a safe place or inside of the electricity meter cupboard.
RECOMMENDED INSTALLATION LOCATIONS FOR THE SA-240:
Install the first smoke detector near the bedroom. Ensure that it is placed so, if it would detect fire, at least one exit
route would still be accessible. We recommend to place one alarm near each potential blockade of your exit route, so
you are alerted before a fire would block off escape.
Use multiple smoke detectors to increase safety and ensure an alert before the escape route is blocked.
Install at least one smoke detector on each floor of your house.
Install at least one smoke detector in each room where people smoke or where there is equipment that may
potentially cause a fire.
Smoke and heat will first move upwards towards the ceiling; after that the smoke and heat will travel horizontally.
Install the detector on the ceiling. Except for rooms smaller than 1m, you should stay at least 50 cm away from the
wall and 61cm from any corner. Smoke and heat do not gather in such corners, preventing the detector from alerting
you on time.
DO NOT INSTALL IN THE FOLLOWING LOCATIONS:
The kitchen; Steam from cooking might give a false alarm.
The shower or bathroom; water damp might cause a false alarm and the moist environment might damage the
detector.
The garage: The car exhaust might cause a false alarm.
In front of a fan or nearby the exhaust of an air conditioner or heater.
In a ceiling nook.
In rooms where the temperature could reach below 0°C or beyond 40°C.
Do not paint or otherwise cover this smoke detector.
INSTALLATION INFORMATION:
For your own safety; before installation, ensure all mains power has been disconnected. Once the
installation is fully complete, you may reconnect the 230V mains power.
Attach the ceiling plate using the included plugs and screws to the ceiling on a location of choice. Wall mounting
is not recommended for smoke detection. Remove the plastic foil from the backup battery and place it inside the
battery compartment, minding the polarity. Attach the detachable 230V connection cable to the cables leading to the
electricity meter of 230V , you may attach the white link cable to another cable to lead to the lead-cable of any other
SA-240 model to link both models. Do not attach this cable to the earthing cables.
ATTENTION. Do not switch the phase (brown) and 0-(blue) cables. The smoke detector will not function
correctly if you do this.
Now plug the 230V connection cable you installed into the SA-240. The connector only fits at one single angle. Then
place the detector on the ceiling plate and twist it into place. Now reconnect the power to mains. The green LED
should now light constantly. Perform a first test by holding the test key for two seconds. Also see the paragraph:
“Testing”.
EN
Do not place here
Place near here
Minimum distance
SA-240-8712412574636-Manual v2.2
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alecto SA-240 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alecto SA-240 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 3,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info