707317
23
Zoom out
Zoom in
Previous page
1/28
Next page
23
CO concentration
NO ALARM
for
ALARM
for
33PPM 120 min. -
55PPM 60 min. 90 min.
110PPM 10 min. 40 min.
330PPM - 3 min.
In accordance to the EN50291 standard.
When the alarm sounds, it must turn off within 6 seconds after moving the detector to a space with
a CO concentration below 40PPM.
The detector will automatically perform an error check.
BATTERY INFORMATION INDICATION:
The battery is checked automatically.
The green power LED will flash every 40 seconds for as long as the battery power is higher than
3.5 Volts. This means the battery capacity is sufficient. As soon as the battery power drops below
3.5 Volts, a beep tone will be emitted when the green LED flashes briefly. At that time, please
replace the batteries as soon as possible.
Use High Energy Alkaline batteries (3 x LR6 / 1.5V AA).
Remark: Rechargeable batteries are not suitable.
With both the supplied batteries and most A brand batteries on the market, it will take
approximately 7 years before the batteries run empty.
TESTING AND RESET:
Testing:
When the CO detector is working under normal conditions, the sensor and siren should be tested at
least every month by pressing the “TEST/RESET” button.
“ALARM” LEDs will blink. The detector will then emit 3 beeps while the red “ALARM” LED flashes 3
times. It means everything is in order.
If the sensor detects an error, the yellow “FAULT” LED will flash 2 times while 2 beep tones are
emitted.
Reset:
The alarm can sometimes activate because of environmental influences, for example due to smoke
with certain carbon monoxide concentrations or other chemical gases that are not life-threatening.
In this case, you can press the “TEST/RESET” button provided that the CO value is below 150PPM.
The alarm will stop and the detector immediately starts checking the gas again. If the concentration
is above 150PPM, it’ll be impossible to stop the alarm. The red LED continues flashing, but the
siren will stop for 5 minutes. If the concentration is still above 150PPM after those 5 minutes, the
alarm will continue.
ALARM DISPLAY AT ACTIVE ALARM:
When there’s an active alarm, the red “ALARM” LED will illuminate, 3 beep tones are emitted
continuously. When the carbon monoxide concentration drops below 40PPM, the alarm will stop.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alecto COA-29 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alecto COA-29 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info