This CO detector is not a replacement for smoke, fire or other detectors.
This detector cannot protect people with special medical conditions and might not prevent any
chronic health effects of carbon monoxide on the body. This is not a replacement for the correct
installation, use and periodic maintenance of combustion equipment, nor adequate ventilation of
spaces in which these devices are being used.
RECOMMENDED POSITIONING FOR THE COA-29:
Install the CO detector in a bedroom, a hallway near the bedroom or the area near a
combustion device (boiler, water heater, gas stove, etc.). Check whether the alarm can be
heard inside bedrooms.
In houses with multiple floors, it’s recommended to install a CO detector on each floor.
Install the CO detector at least 2 meters away from combustion devices, within the air flow
from the combustion device. In the case of smaller spaces (<4m³), the detector should be
installed outside these spaces.
Install the CO detector in spaces without open combustion devices, preferably 1.50m above the
floor and outside spaces without air flow. In bedrooms, install the detector at ‘face height while
sleeping’.
Install the detector on a spot where the weekly check can be performed easily.
AVOID THE FOLLOWING PLACES FOR INSTALLATION:
Never install the CO detector in spaces without air flow, such as roof ridges, arched ceilings or front
roofs.
Never install the CO detector in the turbulent air from ceiling fans, nor place it near vents with fresh
air or close to doors and windows opening to the outside.
Keep the CO detector away from extremely dusty, dirty or greasy spaces such as kitchens, garages
and heating spaces <4m
³
or pantries. Dust, grease and household chemicals can affect the sensor.
Install the CO detector at least 0.5 meters away from gas discharge lamps (halogen) because of
electronic interferences that can lead to false alarms.
Keep the CO detector away from humid and wet spaces. Do not use spray cans near the CO detector.
Never install the CO detector in spaces with temperatures lower than 0°C or higher than 45°C, and
the humidity higher than 90%RH.
Never install the CO detector behind curtains or furniture. Carbon monoxide must be able to reach
the sensor to ensure the sensor can properly detect carbon monoxide levels. NEVER place the CO
detector flat on a table or similar surface.
INSTALLATION INFORMATION:
Install the dector on a wall using plugs and screws or place it on a table. Insert the batteries into
the detector. The Status LED will briefly illuminate, the detector will emit a short beep tone and the
display briefly lights up. Now install the detector onto the mounting place and press the detector
down until correctly fastened. You can perform the first test by briefly pressing the test button, see
also paragraph “Testing and reset”.
USE:
The CO detector starts functioning after installing the batteries (High Energy Alkaline batteries
1.5V AA - LR6) and mounting the CO detector on the wall. The unit can only be placed onto the
mounting plate with the batteries in place. The green “POWER” LED will flash every 40 seconds
to indicate that the detector is working. When the sensor indicates an empty battery the detector
emits a short beep tone every minute, you should replace the batteries as soon as possible. When
these warnings start, the detector will continue to function correctly for at least 7 days. The table
below shows when the detector will sound the alarm.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alecto COA-29 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alecto COA-29 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info