6. Offset (temperature adjustment)
This function calibrates the temperature on the
panel ±5 °C if you notice that the temperature is
not the same as the temperature shown on the
panel.
Applies also to display of external temperature.
7. Return
To return to the previous menu, press this
symbol.
8. Prio setting
With this function you can choose to prioritise
(select) electricity or gas as the main alternative.
9. Button sound
This function turns button sounds on and off.
10. Backlighting
Standb. Screen can be set to three different
modes, dark, bright and invert.
Dark: Used to turn of screen backlight. The
screen turns off (goes dark) in Standby. Pres-
sing the screen or the menu button while
standby is active will light up the screen but
it will return to dark again after 30 seconds
unless controlled from the panel.
Bright: Used to obtain backlight while the
screen is in standby.
Invert: Used to obtain inverted screen back-
light while it is in standby. Standby is activa-
ted automatically after 30 seconds if the
panel is not touched.
The Brightness of the screen's working mode
can be adjusted between 1-3.
11. Automatic temperature increase
(legionella)
The boiler will start at 02.00 in the morning (if
the clock is set) and run as indicated for “More
hot water” for 30 minutes (see section 5.2).
This is to reduce the risk of legionella.
12. Circulation pump settings
Pump selection: Choice of pump.
*12 V pump, pump capacity is variably adjus-
table with a potentiometer on the back of the
pump (1-5), normal mode is 2, which works in
most cases. Mounted on the boiler.
*PWM controlled 12 V pump, this is a vari-
able speed controlled pump that can be set
to ve different levels (1-5) via the panel,
normal level is 2, which works in most cases.
Mounted on the boiler
*Extra 12 V pump, often located in the
expansion tank.
*230 V pump. Often used in combination
with an extra 12 V pump located in the
expansion tank.
If you have both a 230 V pump and an extra
12 V pump installed, you will also be able to
select AUTO mode from the menu.
Auto: In this mode, the *230 V pump will
work if 230 V is connected and the extra 12
V pump is activated if 230 V is disconnected.
Pump setting: (Setting)
Cont: With this function selected the pump
is permanently on. (NB. This function limits
the supply of hot water, particularly when
there is a low heating requirement).
Therm: With this function selected the
pump is controlled by the panel/room sen-
sor. This is the normal operating mode for
heating the vehicle and obtaining a normal
supply of hot water.
13. External start
This function is used when starting the boiler
externally. When an external start has been
activated, the panel should be turned off.
External start has three modes: Off, Ext and
230 V. The function is turned off in Off mode.
*Ext. This function is used when starting the
boiler through an external signal. When the
EXT function has been activated, the control
panel’s on/off button must be turned off but
12 V must be connected (vehicle's main switch
on). Before turning off the control panel with the
on/off button, set the parameters/functions that
you want the boiler to have when it starts.
NB! In order to use this function, an
accessory must be installed that can use
external start.
*230 V. This function is used in connection
with starting the boiler when connection of
230 V to vehicle takes place externally. When
the 230 V function has been activated, the
control panel’s on/off button must be turned
off but 12 V must be connected (vehicle's
main switch on). Before turning off the control
panel with the on/off button, set the parame-
ters/functions that you want the boiler to have
when it starts (230 V connected). Certain
vehicles can be equipped with their own solu-
tion, *caravan site connector.
14. Language
This function is used to reset the screen
between different languages. Available
languages are English, French and German.
However, the service menu is only available
in English (see section 8).
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
manufacturer's instructions.
9


Need help? Post your question in this forum.

Forumrules
1

Forum

alde-compact-3020-he---rev-1442

Reset search

  • My heating at night seems to switch on and of within half a minute or so. Should it be that regular.
    Regards D. Davis Submitted on 4-5-2022 at 21:03

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alde Compact 3020 HE - rev 1442 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alde Compact 3020 HE - rev 1442 in the language / languages: English as an attachment in your email.

The manual is 4,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alde Compact 3020 HE - rev 1442

Alde Compact 3020 HE - rev 1442 User Manual - German - 18 pages

Alde Compact 3020 HE - rev 1442 User Manual - Dutch - 18 pages

Alde Compact 3020 HE - rev 1442 User Manual - French - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info