626264
13
Zoom out
Zoom in
Previous page
1/32
Next page
13
GB
Chapter Page
How the boiler is constructed 131.
Technical data 131:1
How the boiler works 132.
The functions of the control panel 132:1
Starting the LPG boiler 142:2
Shutting down the LPG boiler 142:3
Setting for maximum comfort 142:4
Setting the room temperature 142:5
Circulation pump 142:6
Electrical heating 142:7
External start 143.
Water heater 154.
Maintenance of the heating system 155.
Bleeding the heating system 155:1
Useful facts about LPG 156.
Troubleshooting 167.
Guarantee 168.
Read these instructions carefully before you use the
boiler.
The instructions for use are approved in accordance
with CE no. 048 AO-0007 for LPG boiler type 2928.
Data plate and production number are located inside
the metal shell beside the expansion vessel.
HOW THE BOILER IS 1.
CONCTRUCTED
The boiler operates with what is known as constant
temperature, i.e. there is always heated liquid in the
boiler to circulate in the system when the room thermo-
stat calls for heat. In other words there is no time lag
when heat is most needed.
From an air intake on the roof ue terminal, the com-
bustion air is passed through an aluminium hose
into the combustion chamber. The gas valve and the
burner assembly are attached to an easily remov-
able plate screwed to the combustion chamber at the
bottom of the boiler. The water jacket, which consists
of an inner and an outer pipe, is located above the
combustion chamber. The space between these pipes
constitutes the reservoir. Inside the inner pipe there
is a ame damper which consists of a folded sheet
of metal. Its task is to convey the hot exhaust gases
from the burner out towards the water jacket so that
the water is heated. From the top of the water jacket, a
pipe goes up to the expansion vessel. In the expansion
vessel there is a 12-volt pump which circulates the
heated liquid in the system. On the front of the boiler is
the control panel with thermostat knob, cut-out, power
intake and changeover switch. At the top of the boiler
there is a terminal block for making the electrical con-
nection to the boiler. Beside the boiler, a ventilation
duct is attached that takes in fresh air from outside and
conveys it into the boiler but outside the combustion
part itself. The fresh air is heated by the body of the
boiler and convected through the ventilation grille in
the front panel out into the room.
Technical data1:1
Gas: Propane Butane
Power: 5,8 kW 6.7 kW
Gas consumption: Max 420 g/h Max 480 g/h
Gas pressure: I
3+
28-30/37 mbar I
3B/P
30 mbar
Liquid volume (glycol water) in boiler: 2.6 l.
Liquid volume (glycol water) in immersion heater: 1.0 l.
System temperature in the boiler: 35-75
°
C
HOW THE BOILER WORKS2.
When the room thermostat calls for heat, the circula-
tion pump starts. The liquid in the system starts circu-
lating, and cold water comes into the boiler. The sen-
sor on the water jacket senses that the water is colder
than the temperature set on the boiler thermostat.
The main burner ignites and heats up the water that
circulates round the system. When the heat inside the
vehicle has reached the temperature set on the room
thermostat, the circulation pump stops. The sensor
on the boiler senses that the water has reached the
temperature set on the boiler thermostat. It shuts off
the main burner and goes down to a pilot ame. When
the water temperature has fallen a few degrees in the
boiler, the main ame is lit again. In this way there is
always heated water when the room thermostat calls
for heat.
The functions of the control panel 2:1
(g 1)
Normal position for immersion heater. The heating A.
element is controlled by the room thermostat.
Constant position for the immersion heater. The B.
heating element is controlled by the immersion
heater’s thermostat. The changeover switch should
be in this position when the water heater is in use.
1000 watts power on the immersion heater.C.
2000 watts power on the immersion heater. D.
240-volt circulation pump on the immersion heater.E.
12-volt circulation pump on the boiler.F.
Normal position for 12 and 240-volt circulation G.
pumps. The selected pump starts and stops as
indicated by the room thermostat.
Constant position for 12 and 240-volt circulation H.
pumps. The pump runs constantly and the room
temperature is regulated by the boiler’s thermostat
knob, in that the boiler’s system temperature is
adjustable. The constant position uses for exam-
ple when there are many persons in the caravan.
If one sits near the room thermostat it can switch
the circulation pump off, with cold areas near the
windows and oor as a result. In this position the
pump is constantly on and coldness is avoided.
Cut-out 1 A fuse.I.
Power intake 12 V DC auxilary sockel (used for J.
external start etc. See chpt 3:0).
Warning light for ignition spark.K.
Thermostat knob.L.
13


Need help? Post your question in this forum.

Forumrules
1

Forum

alde-comfort-2928

Reset search

  • Where can I get an Alde control house and lid in EUROPE for a 2923/2928? Submitted on 29-8-2021 at 17:16

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alde Comfort 2928 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alde Comfort 2928 in the language / languages: English, German, Dutch, French, Swedish, Finnish as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alde Comfort 2928

Alde Comfort 2928 Installation Guide - English, German, Swedish - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info