601651
16
Zoom out
Zoom in
Previous page
1/160
Next page
en
Storage
16 HWA 3000_3500 Classic
STORAGE
ADVICE
In the event of frost risk, the system must
be drained completely (pump, lines and
storage vessel).
1. Drain the suction line (Fig. B -16) and pres-
sure line(Fig. B -10).
2. Unscrew the drain screw (Fig. A -8) and allow
the water to drain from the pump.
3. The water in the storage vessel (Fig. A -6) is
pushed out at the same time by the air bel-
lows.
4. Screw the drain screw (Fig. A -8) back in po-
sition and store the pump, lines (Fig. B -10,
16) and storage vessel (Fig. A -6) in a frost-
free location.
DISPOSAL
Do not dispose of old
equipment,batteries or accumulators
as householdwaste!
Product, packaging, and accessories
were made with recyclable materials, and
should be disposed of accordingly.
HELP IN CASE OF MALFUNCTIONS
CAUTION!
Disconnect the mains plug before any fault rectification work!
Malfunction Possible cause Rectification
Impeller blocked Clean the pump
Release the motor shaft of the impeller
with a screwdriver.
Overheating by dry running or wa-
ter that is too hot (thermal protection
switch has switched the pump off).
Check the water level on the suction
side.
Allow the conveying fluid to cool down.
Repairing or replacing the pump.
Pump drive motor
does not run
No mains voltage Check the fuses and power supply.
The suction line is not under the water
surface. Dry run, automatic switch-off
after 90 seconds.
Submerge the suction line in the water
by at least 30 cm.
Suction-side blockage Remove dirt from suction area.
Pressure line closed off Open the closing off units in the pres-
sure line.
Pump drawing air in the suction line Check all connections on the suction
line for leaks.
Replacing the seal.
Pump not drawing
water
Pump has been running dry Fill the pump housing with water.
Diaphragm is damaged. Have the diaphragm replaced by AL-
KO Service Department.
Pump switches
on and off too fre-
quently
Low air pressure in storage vessel Top the air up in the storage vessel.
(Set the diaphragm pre-pressure to 1.5
bar).
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko HW 3500 INOX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko HW 3500 INOX in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian as an attachment in your email.

The manual is 3,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info