Startup
477 032_a 15
Switch the pump off
1. Remove the mains plug from the socket
2. Close one of the closing off devices (valve,
spray nozzle, water cock) in the pressure line
(Fig. B -10).
ADVICE
If no suction takes place within a period
of 180 seconds, the garden pump au-
tomatically goes to "fault" condition and
switches off.
CAUTION!
Danger of injury from hot water
In extended use against the closed pres-
sure side (>10 min.), the water in the
pump can be severely heated up and can
be emitted in an uncontrolled manner!
Isolate the unit from the mains and allow
the pump and water to cool down. Start
the unit again only after all the faults have
been rectified!
The risk of injury from hot water can arise if:
the installation is not correct
the pressure side is closed off
there is a lack of water in the suction line, or if
the pressure switch is defective.
Procedure
1. Isolate the unit from the mains and allow the
pump and water to cool down.
2. Check the unit, the installation and water le-
vel.
3. Start the unit again only after all the faults
have been rectified!
MAINTENANCE AND CARE
Check the air pressure in the storage vessel.
CAUTION!
Check the air pressure in the storage
vessel at regular intervals. It must not fall
below 1.5 bar (see section "Commissio-
ning: Checking the air pressure in the
storage vessel").
1. Isolate the house water system from the
mains and secure against switching on again.
The pump stops automatically.
2. Open one of the closing off devices (valve,
spray nozzle, water cock) in the pressure line
(Fig. B -10).
3. Drain the water off until the pump is comple-
tely empty.
4. Open the cover on the back of the storage
vessel.
5. Check the air pressure at the valve with an air
pump or a tyre pump with pressure indicator.
If necessary, correct the air pressure.
6. Then close the cover again on the back of the
storage vessel.
7. Start the house water system again.
Cleaning the pump
ADVICE
After conveying swimming pool water
containing chlorine or fluids that leave a
residue, the pump must be flushed out
with clear water.
1. Isolate the unit from the mains and secure
against switching on again.
The pump stops automatically.
2. Flush the pump out with clear water.
3. Insert the mains plug into the plug socket.
4. Switch the house water system on with the
on /off switch (Fig. A -6).
The pump starts automatically.
Remove blockages
1. Isolate the unit from the mains and secure
against switching on again.
2. Remove the suction hose from pump inlet.
3. Connect the pressure hose to the water sup-
ply.
4. Allow water to run through the pump housing
until the blockage is removed.
5. Check that the pump is running freely by swit-
ching it on briefly.
6. Start the house water system again as descri-
bed.
Pressure Switch
ADVICE
The switch-on and switch-off pressure of
the house water system is pre-set in the
factory. Any changes that may be requi-
red should only be made by the specia-
list dealer.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko HW 3500 INOX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko HW 3500 INOX in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian as an attachment in your email.

The manual is 3,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info