Introduction
Please read the operating instructions carefully
before you use the submersible pump to prevent
accidents and ensure the trouble-free operation
of the pump.
Make sure you keep the instructions at hand for
quick reference. If you resell your pump or give it
to another user, please include these instructions
in the sale or the gift.
The following symbols are used in the instruc-
tions:
!
DANGER
This symbol draws your attention to
work processes or operating proce-
dures that have to be carefully observed
in order to prevent serious injury to the
user or another person.
CAUTION
This symbol draws your attention to
information you need to ensure that
your pump is not damaged due to
improper or careless use.
PLEASE NOTE
The information symbol draws your
attention to essential technical require-
ments.
For Your Safety
!
The submersible pump may only be
connect-ed to an electrical device which
is compliant with DIN/VDE 0100, Parts
737, 738 and 702 (swimming pools).
Make sure that fuse protection in the
form of a 10 A automatic cut-out and a
fault current guard circuit with a nominal
fault current of 10/30 mA is installed.
!
The supply voltage and current specified
on the type plate must be identical with
the voltage and current of your electrical
system.
!
If you need to connect your pump to an
extension cord, make sure that the cable
is 3 x 1.5 mm
2
that it corresponds to type
H07RN-F and is compliant with
DIN 57282/57245. The connector must
be splash-proof. Cable drums must be
completely unwound.
!
The submersible pump may not be
operated by anyone
who has not read or does not fully
understand the operating manual or
is under the age of 16.
!
The submersible pump may not be used
for any other than its designated use.
Before putting the pump into operation,
make sure that
the submersible pump, the electric
cable and the plug are not worn or
damaged and
Nobody is near, touching or in the
liquid to be pumped.
!
Do not operate the submersible pump if
it is damaged. Necessary repairs must
be carried out in a qualified AL-KO
service centre.
!
Never use the electric cable to lift, carry
or attach the submersible pump to an-
other object. Do not pull on the cable
when unplugging the pump.
!
Make sure that the pump is unplugged
before beginning any maintenance,
repair or cleaning work. In the event of a
malfunction, immediately unplug the
pump. Make sure that the plug does not
get wet.
!
Do not attempt to make any changes or
modifications to the submersible pump
by yourself. You may endanger your life
or invalidate the warranty.
Use
Designated use
The submersible pump is designed for home use
in your house or garden. Please observe the
technical data given in the instructions before
putting the pump into operation.
Your submersible pump has been designed for
use in the following applications:
emptying your cellar or house after a flood,
emptying containers or pumping liquid from
one container into another,
pumping water from wells,
aerating garden ponds or artificial brooks
and streams,
emptying drains or cisterns (submersible
pumps, types Drain only).
The submersible pump is designed to pump only
the following liquids:
clear water,
Translation of original user instructions GB 1
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko DRAIN 6004 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko DRAIN 6004 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info