Model No: AC -S24CK_S24HK
Version 1.0
refrigerant.
F If the system can not be charged with the specified amount of refrigerant, it can
be charged with a little at a time (approximately 150g each time) while operating
the air conditioner in the cooling cycle. However, one time is not sufficient, wait
approximately 1 minute and then repeat the procedure (pumping down pin).
F This is different from previous procedures. Because you are charging with liquid
refrigerant from the gas side, absolutely do not attempt to charge with larger
amounts of liquid refrigerant while operating the air conditioner.
l Immediately disconnect the charge hose from the 3-way valve’s service port.
F Stopping partway will allow the gas to be discharged.
F If the system has been charged with liquid refrigerant while operating the air
conditioner before disconnecting the hose.
l Mount the valve caps and service port cap.
F Use torque wrench to tighten the service port cap to a torque of 1.8kg.m.
F Be sure to check for gas leakage.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Akira AC-S24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Akira AC-S24 in the language / languages: English as an attachment in your email.

The manual is 6,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info