1. Remove the power supply cable that is
connected to the indoor unit!
2. To connect the indoor units to the outdoor unit,
use the following electrical cables.
3.
4. Connect the cable ends to the terminals of the
indoor and outdoor units, as shown in
fig7.Please select corresponding connection
according to the different indoor units.
5. Secure the multiple wire power cable with the
cable clamps.
Prepare the cable ends for the power input and
for the cables between outdoor and indoor
units as shown in figure 6a and 6b respectively.
ELECTRICAL CONNECTION BETWEEN AND UNITOUTDOOR INDOOR
Fig.5
1. Terminal
2. Cable clamp
NOTES:
The wire color code can be selected by the
installer.
ELECTRICAL REQUIREMENTS
Electrical wiring and connections should be made
by qualified electricians and in accordance with
local electrical codes and regulation. The air
conditioner units must be grounded.
The air conditioner units must be connected to an
adequate power outlet from a separate branch
circuit protected by a time delay circuit breaker, as
specified on unit's nameplate.
Voltage should not vary beyond 10% of the rated
voltage.
Fig7
Fig6a
100
40
8
8
BA
Unit A
Unit B
Unit C
Unit D
2
Fig6b
100
40
8
8
BA
Ú
Unit A
Unit B Unit D
QUATTRO UNIT
TRIO UNIT
Fig.7
1. Indoor unit terminal for WNG.
2. Cable clamp.
3. Indoor Unit terminal for
K, LS, PXD.
4. Power input cable.
5. Outdoor unit connection cable.
6. Power cable in the indoor side
to remove.
NL
1
2
Fig5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airwell Multisplit YAZE QUATTRO DCI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airwell Multisplit YAZE QUATTRO DCI in the language / languages: English as an attachment in your email.

The manual is 0,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info