733806
29
Zoom out
Zoom in
Previous page
1/32
Next page
25
SECURE MAINS CABLE USING ‘PCLIPS FOR LEFT HAND OR RIGHT HAND CABLE MANAGEMENT.
The method of connection to the mains electricity supply
must facilitate complete electrical isolation of the appliance,
by a multi-pole switch, having a contact separation of at least
3 mm on all poles.
The isolator should not be positioned immediately above the
cooker, but must be tted within 2 metres of the appliance.
The isolator maybe separate from the connection point.
The mains connection point must be accessible within the
areas shown in Fig. 17.1 and Fig. 17.2 for cable routing
options.
For 2 or 3 phase installations an optional adaptor kit must be
obtained (Part No. AE4M280352).
17. Electrical connection
Fig. 17.1
Fig. 17.2
DESN 517652
n
WARNING: This appliance must be earthed.
n
This appliance is designed for the voltage stated on
the rating plate, which is situated behind the plinth
cover.
n
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualied person to avoid a hazard.
For the cooker
Two seperate phase 13 AMP 230V or 3PH 400V minimum
16A per phase ~ 50 Hz fused electrical supply are required
adjacent to the appliance. External wiring to the unit must
be installed using the mains cable provided, in accordance
with the current wiring regulations and any local regulations
which apply. If the cable is shortened, new ferrules must be
tted to the stripped conductors.
450mm MAX
2
metres
2 metres
WORKTOP
WORKTOP
THE MAINS SUPPLY MUST BE WITHIN THE ZONES SHOWN. IF A RECESSED COOKER CONNECTION IS TO BE
USED BEHIND THE APPLIANCE WITHIN THE HATCHED AREA ALLOW A 5mm GAP AT REAR OF APPLIANCE.
Cable point for 3m long 13A cable supplying the two hotplates
Cable point for 3m long 13A cable supplying main cooker.
SECURE MAINS CABLE USING ‘P CLIPS FOR LEFT HAND OR RIGHT HAND CABLE MANAGEMENT.
WORKTOP
2.5 metres
450mm MAX
2.5 metres
WORKTOP
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aga R3 Series 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aga R3 Series 100 in the language / languages: English as an attachment in your email.

The manual is 5,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info