Default Protocol: this is the protocol used by default for setting an outgoing call. You can find
here the three possible AoIP session types: SIP (unicast), Direct RTP (unicast), or Multicast. SIP
is the standard choice, "Direct RTP" is a mode without signaling, used for instance for
compatibility with devices that do not support SIP.
STUN Mode: enable or disable STUN. In this way you can disable STUN without erasing the
STUN server address.
STUN Server: enter the address of the STUN server, either in numeric form or with a symbolic
name. This kind of server allows Scoopy+ S to discover its public IP address when it accesses the
Internet through a router with NAT. You can use AETA’s server: stun.aeta-audio.com.
SIP Registration: enable or disable the registration on a SIP registrar server. The following
menus SIP xxx are used to enter the parameters of the account (or the accounts) on this
server, when using such service. These parameters should be provided by the administrator of
the SIP server. With this SIP Registration parameter, you can disable the registration and
hence stop using a SIP server, without having to erase account parameters; these stay ready for
later use.
SIP Accept calls: when this box is checked, the codec accepts incoming SIP calls (regardless
whether the codec is registered or not on a SIP server). If it is not checked, incoming SIP calls
are rejected, with a "busy" indication.
SIP User: enter the user ID as provided with the account. This field corresponds to a number
that a remote party can call to initiate a link with the codec when it is registered on the server.
If this field is left empty, the unit does not register on the SIP server.
SIP Display Name: this (optional) parameter may be displayed by the remote agent during a
link; you can enter any text you wish. If this field is left empty, the actual value is the SIP URI of
the unit.
SIP Registrar: URL of the SIP server, in case one is used. You can also enter a numeric IP
address.
SIP Auth User: enter here the authentication ID as provided with the account. If this field is
left empty, the actual parameter is the same as the SIP User field, which is appropriate in most
cases.
SIP Auth Password: password provided with the SIP account.
SIP Outbound Proxy: IP address or domain name of a proxy server through which SIP
transactions and audio streams are relayed. This parameter is optional, to be filled only is such
server is used in the organization.
Note : contrary to the SIP registration data, this parameter is active even if "SIP Registration"
is disabled.
Keepalive Interval: whenever necessary, the codec performs transactions to "keep alive" a
translation through a NAT router. This setting defines the maximum time left between two
transactions with the SIP server. It should be set on a value lower than the NAT translation time
out of the router.
Min. Regist. Period : sets the interval between two re-registrations on the SIP server. Actually
the server always imposes a maximum period; therefore this setting is optionally used to make
the registration renewal more frequent, if its value is lower than the time set by the SIP server.
SIP port: the default port for SIP signaling is 5060 (UDP), you can enter a different value here.
Note: this port number is valid for the SCOOPY+ S itself, not for the server. For the server side, if a
non-standard port is used, e.g. 5070, the "SIP Registrar" field must specify the port after a
colon like in "mySIPserver:5070".
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeta Scoopy plus S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeta Scoopy plus S in the language / languages: English as an attachment in your email.

The manual is 5.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info