618082
17
Zoom out
Zoom in
Previous page
1/36
Next page
17
F11 OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-7285-r01 (5/3/13)
Set RTI (Repeating Time Interval) Alarm, information includes (Fig. 30):
> Graphic RTI with min_sec icons.
> Time (min:sec).
> Graphic ON (or OFF), flashing.
A (< 2 sec) - to step forward through the selections of OFF, ON, and SET.
M (< 2 sec) - to step back through the selections.
S (2 sec) - to step back to Set SRT.
S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set RDI Alarm.
> If SET is saved, the Minute digits will flash.
A (< 2 sec) - to step upward through the Minute set points from 0: to 9: one at a time.
M (< 2 sec) - to step back through the Minute set points one at a time.
S (2 sec) - to step back to SET flashing.
S (< 2 sec) - to save the Minute setting and flash the Seconds digits.
A (hold) - to scroll upward through the Second set points at a rate of 8 per second from :00* to :59 in increments of 1 second.
*Starts at :10 (sec) minimum when Minutes are set for 0: (min).
A (< 2 sec) - to step upward through the Second set points one at a time.
M (< 2 sec) - to step back through the Second set points one at a time.
S (2 sec) - to step back to Minutes digits flashing.
S (< 2 sec) - to save the min:sec setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved.
Set RDI (Repeating Depth Interval) Alarm, information includes (Fig. 31):
> Graphic RDI.
> Depth interval with FT (or M) icon.
> Graphic ON (or OFF), flashing.
A (< 2 sec) - to step forward through the selections of OFF, ON, and SET.
M (< 2 sec) - to step back through the selections.
S (2 sec) - to step back to Set RTI Alarm.
S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set DA1 Alarm.
> If SET is saved, the Depth digits will flash.
A (hold) - to scroll upward through the Depth set points at a rate of 8 per second from 10 to 100 FT (3 to 33 M) in increments
of 1 FT (1 M).
A (< 2 sec) - to step upward through the set points one at a time.
M (< 2 sec) - to step back through the set points one at a time.
S (2 sec) - to step back to SET flashing.
S (< 2 sec) - to save the setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved.
Set DA1 Depth Alarm (DA2 to DA6 similar), information includes (Fig. 32):
> Graphic DA1.
> Depth with FT (or M) icon.
> Set point ON (or OFF), flashing.
A (< 2 sec) - to step forward through the selections of OFF, ON, and SET.
M (< 2 sec) - to step back through the selections.
S (2 sec) - to step back to Set RDI Alarm.
S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set DA2 Alarm.
> If SET is saved, the Depth digits will flash.
A (hold) - to scroll upward through the Depth set points at a rate of 8 per second from 10 to 495 FT (3 to 150 M) in increments
of 1 FT (1 M).
A (< 2 sec) - to step upward through the Depth set points one at a time.
M (< 2 sec) - to step back through the Depth set points one at a time.
S (2 sec) - to step back to SEt flashing.
S (< 2 sec) - to save the Depth setting and display the Set DA1 Audible screen.
Fig. 32 - SET DA DEPTH
Fig. 31 - SET RDI ALARM
Fig. 30 - SET RTI ALARM
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris F11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris F11 in the language / languages: English as an attachment in your email.

The manual is 7,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email