A300 CS OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-7287-r04 (8/21/14)
BATTERY REPLACEMENT
The procedures that follow must be closely adhered to to avoid entrance of water into the unit. Dam-
age due to improper Battery replacement (or subsequent leakage of moisture into the unit) is not
covered by the A300 CS's 2 year warranty.
The Battery Compartment should only be opened in a dry and clean environment with extreme care taken to prevent the entrance
of moisture or dust.
As an additional precautionary measure to prevent formation of moisture in the Battery Compartment, it is recommended that the
Battery be changed in an environment equivalent to the local outdoor temperature and humidity (e.g., do not change the Battery
in an air conditioned environment then take it outside during a hot sunny day).
Inspect the Buttons, Lens, and Housing to ensure they are not cracked or damaged. If there is any sign of moisture inside the unit,
DO NOT attempt to use it for diving until it receives proper service by the AERIS factory or an Authorized Regional Facility.
Data Retention (calculations & settings)
When the battery is removed, settings* and calculations for repetitive dives are retained in volatile memory until a new battery is
installed.
*Date will have to be set, Time may require adjustment for the time duration that the battery remains out of the unit.
After the Battery is replaced during a 24 hour period after dives, a screen displaying the graphics DATA SAVED CALIBRATE
COMPASS displayed for 3 seconds (Fig. 96) that will then switch to the Compass Calibrate Face Down screen.
> Calibrate the Compass.
Refer to page 45.
> Verify all Set points prior to diving.
BATTERY REMOVAL
Locate the Battery Cover on the end of the housing:
Apply a coin to the recessed slot of the Cover and turn it counter clockwise out of the housing (Fig. 97).
Remove the Battery and discard it according to local regulations governing disposal of Lithium batteries.
INSPECTION
• Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing.
• Inspect the Buttons, Lens, and Housing to ensure they are not cracked or damaged.
• Remove the Battery Cover O-ring and inspect it for any signs of deterioration or deformity. DO NOT use tools to remove the
O-ring.
• To ensure proper sealing, O-ring replacement is highly recommended each time the Battery is replaced.
• Closely examine the Battery Cover and Housing for any signs of damage that might prevent proper threading.
• Closely examine the inside of the Battery Compartment for any signs of corrosion indicating entrance of moisture into the
unit.
WARNING: If damage, moisture, or corrosion is found, return your unit to an Authorized AERIS
Dealer, and DO NOT attempt to use it until it has received factory prescribed service.
BATTERY INSTALLATION
Lightly lubricate the new Battery Cover O-ring with silicone grease and install it onto the Battery Cover. DO NOT roll the
O-ring over the Threads, instead stretch it slightly to work it down over the slotted end of the Cover into the groove at the base
of the threads (Fig. 98).
The O-ring must be a genuine AERIS part that can be purchased from an Authorized AERIS Dealer.
Use of any other O-ring will void the warranty.
• Insert a new CR2 Lithium 3 Volt Battery (Duracell or equivalent) positive (+) side first into the Battery compartment with the
negative end facing out (Fig. 99).
• Ensure that the Battery is properly installed and the Cover O-ring is evenly seated around the Cover.
• Carefully place the Cover (with spring) into the housing and turn clockwise slowly by hand to ensure proper threading.
• Apply a coin and tighten the Cover by turning it clockwise until secure (Fig. 100). The outer surface of the Cover should be
flush with the outer surface of the housing.
----------------------------------------------------------------------------------------------------------------------------------------------
Fig. 97 - REMOVING THE
BATTERY COVER
Fig. 98 - INSTALLING THE
COVER O-RING
Fig. 99 - INSERTING THE
BATTERY
Fig. 100 - COVER
SECURED
DATA S AV E D
C A L I B R AT E
CO M PA S S
Fig. 96 - CALCULATIONS
& SETTINGS
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 CS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 CS in the language / languages: English as an attachment in your email.

The manual is 7,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info