618071
53
Zoom out
Zoom in
Previous page
1/64
Next page
53
A300 CS OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-7287-r04 (8/21/14)
ALTITUDE SENSING AND ADJUSTMENT
Prior to the first dive of a series of repetitive dives, Altitude (i.e., ambient pressure) is measured upon activation then every 15
minutes until a dive is made.
> Measurements are only taken when the unit is dry.
> Two readings are taken, the second reading 5 seconds after the first. The readings must be within 1 foot (30 cm) of each
other to record that ambient pressure as the current Altitude.
> No adjustments are made during any time that the Wet Contacts are bridged.
When diving in high altitude waters from 3,001 to 14,000 feet (916 to 4,270 meters), the A300 CS automatically adjusts to
these conditions providing corrected Depth, and reduced No Deco and O2 Times at intervals of 1,000 feet (305 meters).
At an elevation of 3,001 feet (916 meters), Depth calibration automatically changes from feet of seawater to feet of fresh water.
This is the first adjustment to the algorithm.
When the Conservative Factor feature is set On, NDLs are calculated based upon the next higher 3,000 foot (915 meter) Alti-
tude. All adjustments for Altitudes greater than 11,000 feet (3,355 meters) are then made to allowable dive times for 14,000
feet (4,270 meters). At Sea Level, calculations are based upon an Altitude of 6,000 feet.
The A300 CS will not function above 14,000 feet (4,270 meters).
---------------------------------------------------------
CARE AND CLEANING
Protect your unit from shock, excessive temperatures, exposure to chemicals, and tampering. Protect the lens against scratches
with a Instrument Lens Protector. Small scratches will naturally disappear underwater.
• Soak and rinse the A300 CS in fresh water at the end of each day of diving, and check to ensure that the areas around the
low pressure (depth) sensor (Fig. 95a), data port (Fig. 95b), and buttons are free of debris or obstructions. Soak and rinse
the regulator with the transmitter attached.
• To dissolve salt crystals, use lukewarm water or a slightly acidic bath (50% white vinegar/50% fresh water). After removal
from the bath, place the A300 CS and the regulator assembly with transmitter under gently running water and towel dry
before storing.
• Transport your A300 CS system cool, dry, and protected.
INSPECTIONS AND SERVICE
Your A300 CS should be inspected annually by an Authorized AERIS Dealer who will perform a factory prescribed function
check and inspection for damage or wear. To keep the 2 year limited warranty in effect, this inspection must be completed one
year after purchase (+/- 30 days).
AERIS recommends that you continue to have an inspection performed every year to ensure it is working properly. The costs of
annual inspections are not covered under the terms of the 2 year limited warranty.
To Obtain Service:
Take your A300 CS to an Authorized AERIS Dealer.
To return your A300 CS to AERIS:
Record all data in the viewable Log and/or download the data in memory. All data will be erased during factory service.
Package it using a protective cushioning material.
Include a legible note stating the specific reason for return, your name, address, daytime phone number, serial number(s),
and a copy of your original sales receipt and Warranty Registration Card.
Send freight prepaid and insured using a traceable method to AERIS.
If shipping to AERIS, obtain an RA (Return Authorization) number by contacting AERIS Customer Service at 510/346-0010
x764 or send an email to service2@diveaeris.com.
Non warranty service must be prepaid. COD is not accepted.
Additional information is available at the AERIS web site >>>>
diveaeris.com
---------------------------------------------------------
Fig. 95 - CASE BACK
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 CS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 CS in the language / languages: English as an attachment in your email.

The manual is 7,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info