618071
9
Zoom out
Zoom in
Previous page
1/64
Next page
9
A300 CS OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-7287-r04 (8/21/14)
BRIGHTNESS CONTROL
The level (%) of screen Brightness can be adjusted by accessing the Brightness Adjustment screen while viewing the Home Menu
screen, or a Surface or Dive Main screen (NORM, GAUG, or FREE), or the Compass OP Main screen.
A (2 sec), while on the surface or during dives, will access a Brightness adjustment screen with the last % highlighted and
flashing. During a Low Battery Warning or Alarm condition, the level will be limited to 60% maximum.
ADJUST BRIGHTNESS, information is to include (Fig. 10):
> xx % (last value saved), flashing.
S (2 sec) to step back to the screen from which access was gained without changing the % value.
A (< 2 sec) to step upward through values of 10% to 100% one at a time in increments of 10%.
M (< 2 sec) to step down through values one at a time.
S (< 2 sec) to save the % setting and revert to the screen from which access was gained.
TIP: When an adjustment is made during a dive that is lower than the Auto Dim % set prior to the dive, the screen will remain
illuminated at the level you save until you adjust it to a % level above the Auto Dim % set.
AUDIBLE ALARM
While operating in NORM or GAUG Mode, the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it
is set Off. During that time, the Audible can be acknowledged and silenced by pressing S (< 2 sec).
The Audible will not be active when it is set OFF (a Set Alarms Menu selection).
FREE Dive Mode alarms, which emit 3 short beeps either 1 or 3 times, cannot be acknowledged or set OFF.
Alarms that strike during operations in Compass Mode are described on page 45.
Situations that will activate the NORM/GAUG 10 second Alarm include -
** Items apply only in NORM mode.
• Air Time Remaining (ATR) at 5 minutes, then again at 0 minutes.
• Turn Pressure at the value set (Transmitter 1 only).
• End Pressure at the value set (active Transmitter).
• Descent deeper than the Depth Alarm value set.
• Dive Time Remaining at the value set**.
• Elapsed Dive Time at the value set.
• PO2 level at .20 < value set for the gas in use and again at the value set**.
• O2 accumulation at 240 OTU (80%), then again at 300 OTU (100%)**.
• TLBG at the value set**.
• Ascent Rate (alarm = all 5 segments) exceeds 60 FPM (18 MPM) when deeper than 60 FT (18 M), or 30 FPM (9 MPM) at
60 FT (18 M) and shallower.
• Loss of the active Transmitter Link signal for more than 15 seconds during a dive.
• Entry into Decompression (Deco)**.
• Conditional Violation (above a required Deco Stop Depth < 5 minutes)**.
• Delayed Violation (above a required Deco Stop Depth => 5 minutes)**.
• Delayed Violation (a Deco Stop Depth > 60 FT/18 M is required)**.
• Delayed Violation (Depth > 330 FT/100 M).
• A Gas Switch would expose the diver to PO2 => 1.60 ATA for that gas**.
A single short beep (which cannot be disabled) sounds when -
• 5 minutes elapse on the surface after the Violation dive.
3 short beeps (which cannot be disabled) sound when -
• Ascent Rate (warning = 4 segments) is 51 to 60 FPM (15.1 to 18 MPM) when deeper than 60 FT (18 M), or 26 to 30 FPM
(7.5 to 9 MPM) at 60 FT (18 M) and shallower.
• FREE Dive Repeating Time Interval Alarm - 3 beeps once every 30 seconds, if set On.
• FREE Dive Depth Alarms 1, 2, 3 - 3 beeps 3 times at each value set.
• FREE Dive TLBG Alarm (Caution zone, 7 segments) - 3 beeps 3 times.
• FREE Dive Violation - 3 beeps 3 times upon entry into Decompression.
• FREE Countdown Timer - 3 beeps 3 times when time counts down to 0:00.
During the following situations, the audible will not turn off when acknowledged -
• Delayed Violations 1, 2, 3.
• Deco Stop Depth Violation => 70 FT/21 M stop required.
• FREE mode alarms.
20%
ADJUST BRIGHTNESS
Fig. 10 - BRIGHTNESS
ADJUSTMENT
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 CS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 CS in the language / languages: English as an attachment in your email.

The manual is 7,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info