A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
Set Reference Heading, information includes (Fig. 88) -
> Current Depth with FT (or M) icon, blank on surface.
> Reference Mode icon (2 bars with arrow) with graphic SET (flashing) below it.
> Static Arrow icon (at 12 o'clock), diver direction of travel.
> Dynamic Arrow, tracking Reference direction set.
> Numeric heading (diver's direction), with position graphic.
> On time remaining, counting down, if 15 to 0 (sec).
S (< 2 sec) to flash Heading value, with SET solid.
Rotate (keeping level) in either direction to new Heading.
S (< 2 sec) to lock in new Heading, replacing SET.
Reverse Ref Heading, information includes (Fig. 89) -
> Current Depth with FT (or M) icon, blank on surface.
> Reverse Mode icon (2 bars with arrow) with reverse Heading (180° opposite of Reference Heading set) below it (flashing).
> Static Arrow icon (at 12 o'clock), diver direction of travel.
> Dynamic Arrow, tracking Reference direction set.
> Numeric heading (diver's direction), with position graphic.
> On time remaining, counting down, if 15 to 0 (sec).
S (< 2 sec) to reverse Heading.
The value below the Reverse Mode icon will stop flashing indicating the Heading has been reversed.
CALIBRATION (surface only)
Local magnetic fields can effect display of actual location when reading a digital compass.
It may be advantageous to Calibrate the Compass before its first use after purchase, before use in new global regions, or if inac-
curacies are experienced.
Calibration will be required when the battery is changed.
Upon selecting Calibration on the Compass Menu (by S < 2 sec), a screen appears displaying the graphics CAL with FACE
DOWN UNTIL BEEP (Fig. 90)*.
*This screen will also be accessed after the Battery is changed and Data is either saved or cleared.
To initiate Calibration -
> Turn the unit over (face down, Fig. 90) until it beeps and displays the graphics, then -
turn the unit over (face up), displaying the graphics CAL with FACE UP UNTIL BEEP (Fig. 91) until it beeps, after which a
screen appears displaying the graphics CAL with ROTATE TO CALIBRATE 360° (Fig. 92).
> While keeping it in a flat level position, slowly and steadily rotate* it 360° (
keeping it level is critical for accuracy
), progress
will be indicated by a circle forming on the display (Fig. 93).
*Rotation should take about 15 seconds. If not fully rotated in 15 seconds, operation will revert to the Compass Menu.
Calibration complete -
> Once fully formed, the circle will be replaced with the graphics READY PASSED CALIBRATION (Fig. 94) or FAILED
CALIBRATE AGAIN, flashing for 3 seconds, then -
> If READY, operation reverts to the Compass OP Main.
> If FAILED, operation reverts to the CAL Face Down Until Beep screen for repeat of the procedure.
> If Calibration fails 3 times, operation reverts to the Surface Main screen.
Fig. 88 - SET REF HEADING
(rotate to desired Heading)
Fig. 89 - REVERSE REF
HEADING
(from 260°, to 080°)
Fig. 90 - ACCESS TO CAL
(turn unit upside down)
Fig. 91 - AFTER BEEP
(turn unit right side up)
Fig. 92 - TO START CAL
Fig. 94 - CAL PASSED
Fig. 93 - CAL PROGRESS
(circle forms while rotating)
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 AI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 AI in the language / languages: English as an attachment in your email.

The manual is 11,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info