618070
12
Zoom out
Zoom in
Previous page
1/52
Next page
12
A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
FLY/DESAT
FLY Time is a count down timer that begins counting down 10 minutes after surfacing from a dive from 23:50 to 0:00 (hr:min).
DESAT Time, also a count down timer, provides calculated time for tissue desaturation at sea level taking into consideration the
Algorithm used and the Conservation Factor setting.
DESAT Time also begins counting down 10 minutes after surfacing from a NORM dive, counting down from 23:50 (max, usually
much less) to 0:00 (hr:min).
When the DESAT time reaches 0:00, which will generally occur prior to the FLY count down reaching 0:00, it will remain on the
display until the FLY count down reaches 0:00.
> DESAT is not displayed after a Gauge or Violation dive.
> Desaturation requiring Times greater than 24 hours will display 23: - - .
> In the event that Time to Desaturate still remains at the end of 24 hours, the added time will be zeroed.
> When other screens are accessed, the FLY and DESAT countdowns continue in the background.
Fly/Desat, information includes (Fig. 10):
> Graphics FLY and DSAT with countdown times (hr:min) and Time (clock) icon, dashes if no dive yet.
S (< 2 sec) to revert to Main Menu.
NORM PLAN MODE
No Deco time Limits (NDLs) and O2 time Limits (OTLs) in Plan Mode are based on the Algorithm selected (DSAT or PZ+), the FO2
set for Gas 1, and residual nitrogen (or O2) remaining from previous NORM dives. FO2 set for other Gases are not used for
Plan calculations.
PDPS (Pre Dive Planning Sequence)
Plan screens will sequence through Depths from 30 to 190 FT (9 to 57 M), or the Max Depth that will allow theoretical No Deco
Dive Time of at least 1 minute based upon the previous dive profiles in a series of repetitive dives and taking into account descent
and ascent rates of 60 FPM (18 MPM).
When the Conservative Factor is set On, NDLs are reduced to the values of the next 3,000 foot (915 meter) higher Altitude.
Refer to tables in back.
PDPS, information includes (Fig. 11 A - C):
> Plan Depth value with FT (or M) icon.
> Nx and (PZ+) icons, if they apply.
> Max Depth allowed with FT (or M) and MAX, if Nx.
> Graphic NDC (or OTL) with Dive Time allowed (min).
> Graphic GAS 1 with FO2 icon.
> Graphic AIR; or PO2 alarm value set with icon and FO2 Nitrox value set, if Nx.
A (hold) to scroll forward through screens at a rate of 4 per second increasing planned Depth from 30 to 190 FT (9 to 57
M) in increments of 10 FT (3 M).
A (< 2 sec) to step forward through screens.
M (< 2 sec) to step back through screens.
S (< 2 sec) to exit and revert to the Main Menu.
LOG MODE
Information from the latest 24 NORM and/or GAUG dives is stored for viewing. After exceeding 24 dives, the most recent dive
is stored while the oldest is deleted.
> Dives are numbered from 1 to 24 starting each time NORM (or GAUG) Dive Mode is activated. After 24 hours elapse with
no dive, the first dive of the next period of operation is #1.
> 10 minutes after a dive, the Log screens for all dives stored can be viewed.
If a dive’s elapsed time (EDT) exceeds 599 (min), data at the 599 interval is recorded in the Log upon surfacing of the unit.
Main Menu >> Log Menu >> Dive >> Data 1 >> Data 2 >> Data 3.
Log Menu, information includes (Fig. 12):
> Graphics LOG and MENU with mode (book) icon.
> Listing* of dives displaying - - Number (1 to 24), Date, and start Time; or graphics NO DIVES YET if a new unit.
*Up and Down arrows are not displayed at the right due to space limitations.
A (hold) to scroll forward (down) through the listing at a rate of 8 entries per second.
A (< 2 sec) to step forward (down) through the listing.
M (< 2 sec) to step back (up) through the listing.
S (< 2 sec) to access that dive's Log Data 1 screen.
S (2 sec) to revert to Main Menu.
Fig. 10 - FLY/DESAT
Fig. 11A - PDPS
(Gas 1 set for Air)
Fig. 11B - PDPS
(Gas 1 set for Nitrox)
Fig. 11C - PDPS
(times controlled by O2)











Press S (< 2 sec) to
access Log Menu.
Fig. 12 - LOG MENU
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 AI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 AI in the language / languages: English as an attachment in your email.

The manual is 11,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info