A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
NORM Mode >> for Air and Nitrox SCUBA activity with up to 4 Gases and Pressure from 1 tank (by hose integration).
GAUG Mode >> for SCUBA activity with Pressure from 1 tank (by hose integration).
If no previous dive has been taken within the past 24 hours, NORM is the default mode upon activation with others ac-
cessed as described later.
At any time while operating in Surface Modes, operation will enter the Dive Mode selected upon descent to 5 FT (1.5 M) for
5 seconds.
• When Wet Activation is set Off, Dive Mode will only be activated when the unit is first activated and operating in a
surface mode.
• When Wet Activation is set On, the selected Dive Mode will activate upon descent regardless of whether it is activated
and operating first.
TRANSITION PERIOD, upon surfacing:
Operation shifts from Dive Mode to Surface Mode upon ascent to 2 FT (0.6 M) for 1 second; however, Surface mode
screens will not be available until a Transition time elapses.
The reason for this is that making a descent during the first 10 minutes after surfacing from a NORM or GAUG dive is a
continuation of that dive.
A descent made after the 10 minute interval has elapsed is then considered a new dive.
During the first 10 minutes after surfacing from a NORM or GAUG dive, the Dive Main screen will be displayed with Sur-
face Interval time replacing Current Depth. Dive ALTs can be accessed to view other information pertaining to that dive.
POWER SAVER MODE (PSM)
Once 10 minutes elapse, after the 10 minute Transition Period on the surface after a dive, the unit will enter a Power Saver
Mode (PSM) which turns the display screen off until a button is pressed at which time it will turn back on.
During the time that the screen is off, all operations continue as normal in the background with current updated information
displayed as soon as the screen comes on again.
OPERATING MODES
Pay special attention to items marked with this Warning symbol.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 AI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 AI in the language / languages: English as an attachment in your email.

The manual is 11,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info