A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
AUDIBLE ALARM
While operating in NORM or GAUG Mode the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it is set Off. During that
time, the Audible can be acknowledged and silenced by pressing the S button (less than 2 seconds).
An LED Warning Light, on the housing, is synchronized with the Audible and flashes as the Audible sounds. It will turn Off when the Alarm is silenced. The
Audible and LED will not be active if the Audible is set OFF (a group A setting).
Alarms that strike during operations in Compass Mode are described on page 39.
Situations that will activate the NORM/GAUG 10 second Alarm include -
** Items apply only in NORM mode.
• Air Time Remaining (ATR) at 5 minutes, then again at 0 minutes.
• Turn Pressure at the Set Point selected (Tank 1 only).
• End Pressure at the Set Point selected (Tank 1 only).
• Descent deeper than the Depth Alarm Set Point selected.
• Dive Time Remaining at the Set Point selected**.
• Elapsed Dive Time at the Set Point selected.
• PO2 (for Gas in use) level at .20 < Set Point and again at the Set Point selected**.
• O2 accumulation at 240 OTU (80%), then again at 300 OTU (100%)**.
• TLBG at the Set Point selected**.
• Ascent Rate exceeds 60 FPM (18 MPM) when deeper than 60 FT (18 M), or 30 FPM (9 MPM) at 60 FT (18 M) and shallower.
• Entry into Decompression Mode (Deco)**.
• Conditional Violation (above a required Deco Stop Depth < 5 minutes)**.
• Delayed Violation (above a required Deco Stop Depth => 5 minutes)**.
• Delayed Violation (a Deco Stop Depth > 60 FT/18 M is required)**.
• Delayed Violation (Depth > 330 FT/100 M in NORM, > 400 FT/120 M in GAUG).
• A Gas Switch would expose the diver to PO2 => 1.60 ATA**.
A single short beep (which cannot be disabled) sounds when -
• After 5 minutes on the surface after the Violation dive.
3 short beeps (which cannot be disabled) sound when -
• Ascent Rate is 51 to 60 FPM (15.1 to 18 MPM) when deeper than 60 FT (18 M), or 26 to 30 FPM (7.5 to 9 MPM) at 60 FT (18 M) and shallower.
During the following situations, the audible will not turn off when acknowledged -
• Delayed Violations.
• Deco Stop Depth Violation => 70 FT/21 M stop required.
PC INTERFACE
Interface with a PC, to allow uploading settings and downloading data, is accomplished by connecting the A300 AI to a PC USB Port using the special
USB Interface Cable.
The software program together with the USB Driver required is on the ACI (AERIS Computer Interface) CD, and can be downloaded from the AERIS web
site. The program's HELP** serves as the user manual which can be printed for personal use.
**Prior to attempting to Download data from your A300 AI or Upload Settings to it, review the HELP section of the ACI program. Recommended is to
print those sections of HELP that you consider appropriate for your Interface activities.
The Settings Upload portion of the ACI program can be used to set/change the Set A group (Alarms), Set U group (Utilities), Set T (Time), etc. using the
same Interface System. FO2 related items must be set using the control buttons.
Information available for retrieval (download) from the A300 AI to the PC Download portion of the program includes dive data such as number, surface
interval time, maximum depth, elapsed dive time, no deco status, start/end pressure, start date/time, lowest temperature under water, sampling rate, dive
profile, and Set Points.
The ACI program also allows upgrade of select versions of the A300 AI's firmware (operating system software) after which the A300 AI resets all operating
data. Since the upgrades require reset of the A300 AI, they are blocked during 24 hours after dives.
Refer to page 41 for more details relating to ACI and PC Interface.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 AI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 AI in the language / languages: English as an attachment in your email.

The manual is 11,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info