For the Fitter
2.3.4 Electrical Connection
The storage heater appliance is connected to a load current (OFF-PEAK tariff) and control cables
for the room thermostat and for the charge control (A1/Z1; A2/Z2). The cables A1/Z1 and A2/Z2
are at line-voltage 230V~ and may thus be run together with a L/N/PE cable for the room
thermostat. The heater is suitable for direct connection without a spur, or with a wall socket.
According to regulations every branch circuit must be individually protected, for instance by
circuit breakers for all phases. These circuit breakers must have contact openings of at least
3 mm.
Each heater must be connected to a separate current carrying cable from the electrical
junction box. Running the load current cable from heater to heater is not allowed.
Since the technical connection conditions stipulated by the power supply companies permit a
1-phase connection of up to 2 kW only, the appliance must always be connected to 3 phases.
When connecting to a charge control with a so-called "single-wire control", bridge the
terminals “A2/Z2” and “N”.
Make sure the earth wire is correctly and firmly attached.
2.3.5 Cable Feed
Fig. 9
English
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG WSP 600 HF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG WSP 600 HF in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info