464406
14
Zoom out
Zoom in
Previous page
1/54
Next page
14
for the professional installer
2. Installation instructions
This unit may only be erected and electrically connected by a specialist following the installation
instructions.
First remove the packaging and check accessories and any enclosures, ensure that no accessories remain
in the packaging material.
2.1 Structure of unit
4 Air outlet grid
5 Wall bracket
6 Closing bolt
7 Mains connection cable
8 Rating plate
Technical data
Type WKL503S
WKL503U
WKL753S
WKL753U
WKL1003S
WKL1003U
WKL1503S
WKL1503U
WKL2003S
WKL2003U
WKL2503S
WKL2503U
WKL3003S
WKL3003U
Height mm 450
Width mm 370 445 445 590 740 890 1040
Depth
with wall bracket
mm
78
100
Dimension A mm 121 195 195 343 491 639 787
Weight kg 4,0 4,6 4,6 6,0 7,2 8,4 9,9
Connection 1/N ~ 230 V
Power kW 0,5 0,75 1,0 1,5 2,0 2,5 3,0
Temperature
adjustment range
ºC approx. 6 to 30
Frost protection ºC approx. 6
Protection class II
Protection mode IP 24, splash water protected
Approval see unit rating palte
2.2 Provisions and specification
The unit should not be operated
– inroomsatriskofexplosionorfirefromchemicals,dust,gasorvapour,
– intheimmediatevicinityofpipesorcontainerswhichtransportorcontainflammableor
explosive substances,
– iftheminimumdistancesfromadjacentobjectsurfacesarenotobserved.
In workshops or other rooms in which exhaust gases, oil or petrol vapours etc. occur or where solvents
and chemicals are used, persistent odour problems and where applicable contamination can occur.
The unit may only be fitted to a vertical wall, temperature-resistant up to at least 80 °C.
Minimum distances from adjacent object surfaces must be observed.
All electrical connection and installation work must be performed to VDE regulations (0100), the regula-
tions of a competent utility company and the corresponding national and regional regulations.
The unit must not be mounted directly below a wall socket.
If the unit is permanently connected to an AC network (junction box) an isolation distance of
at least 3mm is required on all poles for isolation from the network. For this, circuit breakers,
LS switches, fuses etc. can be used.
Installation with permanent connection cables is not permitted.
The rating plate must be observed. The rated voltage must correspond to the nominal voltage.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG WKL 1003 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG WKL 1003 in the language / languages: English, German, Dutch, French, Polish, Spanish as an attachment in your email.

The manual is 2,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info