For the Fitter
Fig. 2 Fixing the capillary-tube thermostat
Fig. 3 Push on adjuster knob
2.3 Installation and Electrical Connection
The installation and Electrical Connection may
only be carried out by a competent electrician.
Turn off all electricity supplies to the heater.
To do this, interrupt the electricity supply to
both the charge and the discharge circuits.
Caution: Even if the main circuit breakers
are switched off, some terminals
carrying on-peak current,
especially terminals A1/Z1 and
A2/Z2 can still be live.
Also read the Instruction Leaflet supplied with
the storage heater.
Unscrew and remove the top screw from the
left-hand side panel.
Remove the right-hand side panel and cover
panel of the storage heater. Break out the
knock-outs in the side panel.
Carefully remove the plastic fascia plate from
the inside of the heater front panel using a
screwdriver to gently push out the holding tabs
(Fig. 1).
Attention: The angle of the screwdriver should
be set as close as possible to the
inside of the front panel (oblique
angle prevents breakage of the fascia
plate and/or chipping of the paint-
work).
Fix the capillary-tube thermostat to the fixing
plate through the opening in the front panel
using the M4x6 fixing screws supplied (Fig. 2).
Push the adjuster knob on to the spindle of the
capillary thermostat (Fig. 3).
Make sure that the wires are not touching
any hot surfaces, that they are neither
damaged nor squeezed when replacing the
side panel and that no internal wiring is
touchable from the outside through the
air-slits.
Fig. 1 Plastic fascia plate with holding tab
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG RTi 600 M HF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG RTi 600 M HF in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info