464368
11
Zoom out
Zoom in
Previous page
1/28
Next page
11
For the Fitter
2. Installation instructions
The room temperature regulator must be fitted by an authorised specialist under consideration
of these operation and installation instructions and the operating and installation instructions
of the storage heater.
All electrical connection and installation work must be performed in accordance with the VDE
regulations 0100, the regulations of the electricity supply company responsible and the pertinent
national and regional regulations.
2.1 Technical Data
2.2 Packing Unit
1 Room temperature regulator with four spacers and
- potentiometer with connecting lead
– 6-pole connector with cable harness
1 ON/OFF switch with 2 wires (length 500 mm)
1 temperature selector knob
1 Operating and installation instructions
1 separate double wire (length 500/650 mm)*
1 separate wire with distributor (length 150 mm)*
1 circuit diagram label
1 control panel label
2 cable straps
2 cable twisters
* only needed in connection with ZH 1004 to ZH 1017
2.3 Installation
Disconnect the storage heater from the power supply before starting installation work.
When connecting the storage heater to an automatic charging control unit, there may be
voltage at the terminals A1/Z1 – A2/Z2 even when the fuses are removed.
When installing several storage heaters in a row make sure that the room temperature controller is
installed in the outside right unit. This guarantees that the room temperature can be measured
properly.
2.3.1 Order of Installation
Remove air outlet and inlet grille, front wall and right side wall as described in the storage
heater operation and installation instructions;
Press the dummy caps (1) for the switch and temperature selector knob out of the control panel
at the top and bottom left from the switching area side using a suitable tool (fig. 1).
Installation of the ON/OFF switch:
Push both wires through the cut-out in the metal bracket and snap onto the metal bracket (4)
with the holder (fig. 2).
Press the on/off switch (2) into the holder with the symbol "I" at the right. Push the wires
through the long, oval opening of the angle plate on which the socket strip is mounted from rear
to front and clamp the wires arranged at the centre of the switch to the top terminal strip X2
(LE') and the outside wire to the bottom terminal strip X1 (L) (see page 15 in the circuit diagram).
Fix the potentiometer (5) with plugged on 3-wire connecting lead from the switching area side
to the angle plate (4) with a screw 4 x 10 mm. It should be noted here that the rotary axis of the
potentiometer is turned to the left (anti-clockwise) and the flat side of the rotary axis is facing
to the right (fig. 3).
Lay the 3-wire connecting lead of the potentiometer along the back of the angle plate to the
discharge control unit slot. To do this, pull off the 3-pin plug from the potentiometer, lay the
cable and replace the 3-pin plug.
Model
Rated voltage
Connection rating
Control rating fan
RTi 101 EP
1/N/PE ~ 50 Hz 230 V
16 A with supplementary heater
100 VA
English
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG RTi 101 EP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG RTi 101 EP in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info