Protect PV.500 Operating Instructions
54 of 70 80000031354 BAL
7.2 COM Server
7.2.1 General
The COM server makes the PV inverter data available via an
Ethernet network. A software application can communicate with
the PV inverter via the network using a virtual COM port (this
needs to be installed on a workstation). The COM server is
installed as standard and is used by the AEG service department
for remote maintenance purposes. This calls for an appropriate
Ethernet network with an Internet connection plus a fixed IP
address assignment.
The COM server is located at position A27.
7.2.2 Network Connection
This COM server has an IEEE 802.3-compatible network
connection on a shielded RJ45 plug connector. Its assignment
corresponds to that of an MDI interface, which means the
connection to the hub or switch is made using a 1:1 wired patch
cable.
Ex-works, the COM server operates in an autonegotiation mode on
the network side. This means the data transmission speed and the
duplex process are automatically negotiated with the connected
switch or hub and are set accordingly.
7.2.3 Structure of the COM Server
1
1
CN5
CN1
CN3
Digi
Connect ME
MOD1
H1
gn
gn
ye
Figure 22 – COM server interface (top view)
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV 500 in the language / languages: English as an attachment in your email.

The manual is 1,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV 500

AEG Protect PV 500 User Manual - German - 136 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info