6.3 Remote Signalling
The remote signalling board is a contact interface for signalling PV
messages and controlling PV units. It is supplied as an option for
the AEG PV system and is intended for installation in the PV unit.
The remote signalling master board consists of 5 potential-free
signalling contacts and one control input.
There is an independent 24 VDC power supply for the control in-
put. The control signal is activated by bridging the relevant input.
There is no need for an additional auxiliary power supply.
The signals are assigned as standard or can be configured on a
customer-specific basis. An integrated service switch enables
maintenance work on the unit to be signalled.
Technical data:
The maximum load of the signalling contacts (X3/X4) is
250 V/8 A AC or 50 V/2 A DC.
i
NOTE:
If the specified power has been applied to the relay contacts once,
those contacts can no longer reliably switch an extra-low voltage
(evaporation of the gold alloy)!
The control input (X5) has an independent 24 VDC power
supply. The input is activated via a bridge.
Structure:
K21
K2 2
K23
K24
K25
OPT1
1
1
1
1
X2
1
1
1
1
1
X3
X4
X5
X1
X6
X7
X2
S1
12
11
10
9
8
7
6
5
4
3
2
1
3
2
1
2
1
Fig. 20 Remote signalling master module A12 (top view)
X1: Power supply connection
X2: Connection for remote signalling expansion board
X3/X4: Remote signalling outputs with relay changeover
switches
X5: Remote signalling input via optocoupler with inde-
pendent power supply
X6: Service plug
X7: Connection to a MultiCom interface
S1: Service switch
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV 250 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV 250

AEG Protect PV 250 User Manual - German - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info