6.2 COM Server
6.2.1 General
The COM server makes the serial port of the PV inverter available
via an Ethernet network. A software application can communicate
with the PV inverter via the network using a virtual COM port (this
needs to be installed on a server or a workstation). The COM
server is installed as standard and is used by the AEG service de-
partment for remote maintenance purposes. An appropriate
Ethernet network with an Internet connection and a fixed IP ad-
dress assignment is required here.
An assembly made by W&T is used as the COM server. It is an in-
dustrial version for 10 Mbit and 100 Mbit Ethernet networks. The
COM server is item A27 in the system's AC cabinet; see Figure 4.
6.2.2 Network Connection
This COM server has an IEEE 802.3-compatible network connec-
tion on a shielded RJ45 plug connector. Its assignment corre-
sponds to that of an MDI interface, which means the connection to
the hub or switch is made using a 1:1 wired patch cable.
Ex-works, the COM server operates in an autonegotiation mode on
the network side. This means the data transmission speed and the
duplex process are automatically negotiated with the connected
switch or hub and are set accordingly.
6.2.3 COM Port
Ex-works, the COM port is set so it can communicate directly with
MultiCom interface connector X2 of the PV inverter via RS-232.
6.2.4 Power Supply
The power supply is connected at the screw terminal blocks lo-
cated on the underside of the housing. A DC voltage of any polar-
ity may be used. The protection against polarity reversal means
the following maximum and minimum values apply to the supply
voltage:
12 VDC (-10%) – 24 VDC (+10%)
A corresponding switch mode power supply in the PV inverter
supplies the COM server with power.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV 250 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV 250

AEG Protect PV 250 User Manual - German - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info