Protect PV.250 Operating Instructions
Page 20 of 51 80000027023 BAL, en
4.5.2 Single Operation
Both inverters are switched on and are feeding power into the
mains. The tie switch is open.
This operating mode is active when insolation levels are high.
Fig. 9 Single operation in partner operating mode
Change of status to linked operation:
If the capacity utilisation of the two inverters falls below a certain
value, once a delay has elapsed, the system switches to linked
operation.
The MPP tracker is switched off in both inverters and an attempt is
made to regulate the two inverters to the same DC voltage. When
the DC voltages are approximately identical, the tie switch is
closed. Once the tie switch has been closed, one inverter is
switched off. If the DC voltages cannot be regulated to the same
value in a certain time, the two MPP trackers are switched back
on. Once a delay has elapsed, the MPP trackers are switched
back off again and the next attempt to match the DC voltage is
started.
Change of status to linked operation in the event of a fault:
In the event of a deactivating or self-acknowledging fault in one in-
verter, the two inverters are switched to linked operation.
First, the inverter which is not affected by the fault is also switched
off. The DC voltage is checked. When the DC voltages are ap-
proximately identical, the tie switch is closed and the inverter which
is not affected by the fault is then switched back on. If the DC volt-
ages are still not the same once a certain time has elapsed, the in-
verter which is not affected by the fault is switched back on. After a
delay, a new attempt is made to exit single operation and switch to
linked operation in the event of a fault.
4.5.3 Linked Operation in the Event of a Fault
One inverter is switched on and is feeding power into the mains.
The other inverter has been shut down due to a fault. The tie
switch is closed.
This operating mode is active when one inverter is affected by a fault.
Fig. 10 Linked operation in the event of a fault in partner operating mode
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV 250 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV 250

AEG Protect PV 250 User Manual - German - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info