551733
13
Zoom out
Zoom in
Previous page
1/16
Next page
13
EMPTYING THE DIRT RECEPTACLE
Most models feature dirt receptacles with windows to tell at a glance
when the dirt receptacle should be emptied. In most cases, the dirt
receptacle only needs to be emptied two to three (2-3) times a year.
To remove the dirt receptacle, press the buttons on the receptacle
handles. Remove and empty the contents. Return the receptacle by
attaching the bucket to the power unit. To avoid suction loss make
sure the receptacle is securely attached.
Refer to page 14 - Image 11
FILTER MAINTENANCE
AEG-Electrolux’s exclusive fi lter is permanent and self cleaning.
However, if you have questions about your permanent self-cleaning
lter, please contact your local authorized dealer/distributor.
PAPER BAG FILTERS - OPTIONAL
The volume of the paper bag is 22 liters. A full dust bag reduces
the systems performance. Depending on how often you use your
central vacuum system, the dust bag may need to be changed
2-3 times per year – and can be obtained at your local
dealer/distributor.
Instructions for changing the dust bag:
1. Remove the power unit dirt receptacle
2. Loosen the dust bag from the intake tube, remove and dispose.
3. Place and press the new dust bag fi rmly into the tube.
Turn the dust bag’s opening to make it fasten fi rmly on the tube.
4. Put the dirt receptacle back on the central power unit.
IF YOU EXPERIENCE TROUBLE WITH YOUR
AEG-ELECTROLUX CENTRAL VACUUM
SYSTEM, FOLLOW THE SUGGESTIONS
BELOW BEFORE CALLING FOR SERVICE.
PARTIAL/TOTAL LOSS OF SUCTION POWER
• Be sure dirt receptacle is on properly.
• Empty dirt receptacle.
• Remove debris from fi lter.
• Be sure each inlet valve is properly closed.
CLEAR BLOCKAGE IN PIPES
Blockage in the hose
Plug hose into any inlet valve. If there is no suction through the hose
after connecting at a couple of inlets, the blockage is in the hose.
To clear the hose obstruction, insert a blunt instrument into the hose
(garden hose, wood dowel). You can also attempt to reverse the
suction through the hose to dislodge the blockage.
Refer to page 14 - Image 12 and 13
If there is one inlet valve without normal suction and you have
checked for hose blockage, then the blockage is in the pipe
system between the blocked inlet valve and the power unit
(see instructions below).
Insert the hose into the inlet valve where there is no suction; hold
your hand over the hose end. Release hand quickly. Repeat several
times. If blockage does not clear, contact your nearest AEG-Electrolux
dealer/distributor.
POWER UNIT WILL NOT START
• Check for blown fuse or circuit breaker in main house electric
supply box.
• Unplug and check all wall inlet and low voltage connections
for loose wires.
• If unit still will not start, contact your nearest local authorized
dealer/distributor.
POWER UNIT WILL NOT STOP
• Check inside each inlet valve for obstruction of low-voltage
contacts. If no visual obstruction can be detected, disconnect
the cleaner from the power receptacle and contact your nearest
local authorized dealer/distributor.
CENTRAL POWER UNIT SHUTS OFF BY ITSELF
• Remove and then re-insert hose into inlet or toggle switch off-on
located on hose handle. See “Overload Protection”.
WARRANTY
Warranty is handled by your local authorized dealer/distributor.
Please contact your local authorized dealer/distributor for questions
regarding warranty.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Oxygen - K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Oxygen - K in the language / languages: English, German as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Oxygen - K

AEG Oxygen - K Installation Guide - English - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info