Installation - for contractors
INSTALLATION
7. 
Only a qualied contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1 
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
!

 Higher
 


7.2 
Note
-

The protection rating IP 25 (hoseproof) can only be
ensured with a correctly tted cable grommet.
The specic electrical resistance of the water must
not fall below that stated on the type plate. In a linked
water network, observe the lowest electrical water
resistance (see chapter "Specication / Application
areas / Conversion table"). Your water supply utility
will advise you of the specic electrical water resist-
ance or conductivity.
8. 
8.1 
The following are delivered with the appliance:
Wall mounting bracket
Threaded stud for wall mounting
Installation template
2 twin connectors (cold water with shut-off valve)
Flat gaskets
Cable grommet (power cable from above / below)
Screws / rawl plugs for additional securing of the
back panel when making water connections on n-
ished walls
9. 
9.1 
!


frost.
» Always install the appliance vertically and near the
draw-off point.
The appliance is suitable for undersink and oversink in-
stallations.

26_02_02_1345
1
2
1 Cold water inlet
2 DHW outlet

12
26_02_02_1344
1 Cold water inlet
2 DHW outlet
Note
»  

9.2 
Never operate with preheated water.
A safety valve is not required.
Safety valves are not permissible in the DHW pipe.
» Flush the water line thoroughly.
» Ensure that the ow rate for switching on the appli-
ance is achieved (see chapter "Specication / Data
table", On). Increase the mains water pressure if the
required ow rate is not achieved with the draw-off
valve fully opened.

Use appropriate pressure taps. Open taps are not per-
mitted.
Thermostatic pressure valves must be suitable for hydrau-
lically controlled instantaneous water heaters.
Note

 


Cold water inlet pipe:
Galvanised steel pipe, stainless steel pipe, copper
pipe or plastic pipe
DHW outlet pipe:
Stainless steel pipe, copper pipe or plastic pipe
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG DDLT PinControl 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG DDLT PinControl 24 in the language / languages: English, German, Dutch, French, Polish, Polish as an attachment in your email.

The manual is 34,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info