Operation - for users and contractors
2.3 Test symbols
See type plate on the appliance.
Country-specic approvals and certications:
Germany
A general test certicate as verication of suitability re-
garding noise emissions has been issued for this appli-
ance, based on the State Building Regulations [Germany].
AEG
HOL
DIN 4109
PA-IX 6817/I
3. 
The hydraulically controlled instantaneous water heater
heats water as it ows through the appliance. When a tap
is opened, the heating output starts automatically as soon
as the start-up volume is exceeded (see chapter "Speci-
cation / Data table"). The water volume and temperature
can be adjusted at the tap.
You can choose between 2 output stages. In addition, 2
output stages are hydraulically controlled in relation to the
ow rate.
The ow rate controller compensates for pressure uc-
tuations, thereby ensuring largely stable temperatures.
The controller limits the throughput, thereby ensuring an
adequate increase in the DHW temperature at all times.

The bare wire heating system has a pressure-tested plas-
tic casing. The heating system is suitable for hard and soft
water areas and is largely insusceptible to scale build-up.
This system ensures rapid and efcient DHW availability.
4. Settings
26_02_02_0783
2 1
1 Partial load
At low throughput 1/3 of the heating output is activat-
ed; at higher throughput 2/3 of the available heating
output is enabled. This setting is suitable for hand
washing at a basin, for example.
2 Full load
At a low throughput, 50 % of the heating output is ap-
plied; at a higher throughput the full heating output is
activated. This setting is suitable for washing dishes,
for example.
» Click the output selector into the required position.


» Set the output selector to full power.
4.1 
Note





» 
Low draw-off rate = high outlet temperature
High draw-off rate = low outlet temperature

 
Partial load Washbasin
Full load Bath, shower, sink
» Add cold water if the temperature is too high when
the tap is fully open.

 
Full load All
» Turn the tap lever to the highest temperature.
» Fully open the tap.
» Increase the outlet temperature by closing the tap
slowly.
» Reduce the outlet temperature by adding cold water
or opening the tap further, if possible.

!

-



» -

» 


» 
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG DDLT PinControl 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG DDLT PinControl 24 in the language / languages: English, German, Dutch, French, Polish, Polish as an attachment in your email.

The manual is 34,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info