Installation - for qualied contractors
INSTALLATION
7. Safety
Only a qualied contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
!
Material losses
Observe the maximum inlet temperature. Higher
temperatures may damage the appliance. You can
limit the maximum inlet temperature by installing a
central thermostatic valve.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regula-
tions and instructions.
The protection rating IP 25 (hoseproof) can only be
ensured with a correctly tted cable grommet.
The specic electrical resistance of the water must
not fall below that stated on the type plate. In a linked
water network, observe the lowest electrical water
resistance (see chapter “Specication / Application
areas / Conversion table”). Your water supply utility
will advise you of the specic electrical water resist-
ance or conductivity.
8. Appliance description
8.1 Standard delivery
The following are delivered with the appliance:
Wall mounting bracket
Threaded studs, screws and rawl plugs for the wall
mounting bracket
Installation template
2 twin connectors (cold water with shut-off valve)
Flat gaskets
Cable grommet (power cable from above/below)
Screws/rawl plugs for xing the back panel in the
case of water connection on nished walls
8.2 Accessories
Tap
ADEo 70 WD bath pressure tap
Installation accessories
Pipe assembly, undersink installation UT 104, connec-
tions: Finished walls, G 3/8, top. Water connections with
12 mm compression ttings.
Universal mounting frame
Mounting frame with electrical connections.
Pipe assembly for undersink appliances
This assembly for undersink installation is required if you
need to have the water connections (G A) above the
appliance.
Pipe assembly for offset installation
This pipe assembly with pipe bends is required if you need
to have the appliance vertically offset against the water
connection by approx. 90 mm downwards.
Pipe assembly for replacing a gas water heater
This pipe assembly is required if the installation has exist-
ing gas water heater connections (cold water connection
on the left and DHW connection on the right).
Load shedding relay (LR 1-A)
The load shedding relay for installation in the distribution
board provides priority control for the instantaneous water
heater when other appliances, such as electric storage
heaters, are simultaneously being operated.
ZTA 3/4 - central thermostatic valve
Thermostatic valve for central premixing, for example
for an instantaneous water heater with a solar thermal
system.
9. Preparations
9.1 Installation site
!
Material losses
Install the appliance in a room free from the risk of
frost.
» Always install the appliance vertically near the draw-
off point.
The appliance is suitable for undersink and oversink in-
stallations.
Undersink installation
26_02_02_1345
1
2
1 Cold water inlet
2 DHW outlet
Oversink installation
12
26_02_02_1344
1 Cold water inlet
2 DHW outlet
Note
» Mount the appliance on the wall. The wall must
have a sufcient load-bearing capacity.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG DDLE LCD 27 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG DDLE LCD 27 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 28,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info