- 22 -
3.6 Secondary damper
The secondary damper on the door should always be open while the wood burning stove is in use. This damper
allows you to adjust the wood burning stove to the chimney draft and the heat output you require. In normal
circumstances, the wood burning stove should be working with this damper open between 60 % and 100 %. You
should never close the air intake so far that the flames are extinguished. There should always be visible flames in
order to achieve clean and efficient combustion.
3.7 Primary damper
When you add a new log, the primary air intake/damper should be opened until the fire is burning properly. In order
to utilize the fuel to the fullest extent, the embers should have burnt for so long that it is necessary to open the
primary air intake for approx. 2 minutes to get the new log to burn.
In order to reduce the risk of ash falling from the stove when the door is opened to add more fuel, it is a good idea
to open the primary air intake/damper for approx. 1 minute before the door is opened. This increases the draught
through the stove and reduces the risk that ash will drop on the floor.
Please note: if you overload the wood burning stove and burn more than approx. 2.5 kg wood/hour, there is a risk
that the lacquered surface of the stove will become discoloured and eventually fall off. The stove can be resurfaced,
but this is not covered by the manufacturer’s guarantee. In the same way, any other damage to the stove caused by
overloading will not be covered by the guarantee.
3.8 Aduro-tronic
The patent-applied Aduro-tronic is designed to operate the stove for you. All you have to do is put
dry wood in the stove, and activate the control system - Aduro-tronic does the rest, leaving you to
enjoy the flames and the benefits of efficient combustion. Aduro-tronic is a patent-applied
mechanical solution, which works without the use of electricity.
Please note: Use of dry wood of the right size is important to achieve optimum combustion.
3.8.1 How to operate Aduro-tronic
When lighting
When lighting a fire in the wood burning stove for the first time, the maximum amount of
primary air will be needed to light the fire. For that reason, the primary damper can be
kept “forcibly open”. This is done by pulling the primary damper forward as far as
possible and then fixing it with the Aduro Key (see illustration). When the stove is warm
and a layer of embers has been created on the bottom of the combustion chamber,
the Aduro-tronic can be set to the automatic position, i.e. the Aduro Key can be
removed.
Alternatively, you can leave the door ajar the first minutes during lighting the fire
(without the key).
When stoking
Each time fresh wood is put in the stove, a precise amount of primary air will be allowed in for the first few minutes.
What’s more important is that the primary air is not allowed in for too long. This is to ensure optimum combustion.
The Aduro-tronic control will ensure intake of primary air at the right tempo. The automatic is activated by pulling the
primary damper out each time fresh wood is put in the stove. The automatic closes then the primary air gradually.
Regulation of the Aduro-tronic control
The control is pre-set to allow primary air intake for the first 5 minutes. This setting has been used during testing at
the Danish Technological Institute using ‘standard’ sized logs and with optimum moisture content of 17-20%.
Standard size logs are approx. 30 cm long and 10 x 10 cm in thickness. A standard chimney was also used for
testing. In practice, such circumstances can differ, which is why the Aduro-tronic control can be adjusted to your
circumstances. If you want a slower intake of primary air: (e.g. for a slower flue draught, larger sized wood or for
longer intervals between stoking) Adjust the screw on the front of the control level using a small screwdriver to slow
closure rate. If the screw is turned to the right closing time is increased and if turned to the left closing time is
reduced.
3.9 Ventilation/fresh air supply
In order for the wood burning stove to function at optimum efficiency, air is needed for the combustion process.
There must be sufficient fresh air coming into the room containing the wood burning stove. In very well-insulated
houses, or houses with powerful cooker hoods and/or air conditioning systems, a vacuum can be created around
Aduro Key
Dansk | Deutsch | English | Francais | Svenska
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aduro 11 eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aduro 11 eco in the language / languages: English, German, Danish, French, Swedish as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info