10 Operating a partitioned
system
The installer can program the alarm centre so that it
behaves like 4 separate alarm centres. The partitions are
called partition A, B, C and D. These can be switched
active or inactive independent of each other. Several
partitions can be switched active or inactive
simultaneously; this is set by the installer.
10.1 Control unit
In partitioned systems, buttons A, B, C and D have the
following functions:
Button Meaning
A Active / inactive Partition A
B Active / inactive Partition B
C Active / inactive Partition C
D Active / inactive Partition D
10.2 Activating a partition
1. Enter your user code via the keyboard or hold your
proximity code key at the control unit. If no other partition
is active then the display shows:
If another partition is active then the display shows:
2. Press the required partition button. The display shows:
3. Press .
The display shows which partition the alarm centre is
currently activating and the time until completion of the
process. A beep is emitted at the control unit if this has
been programmed.
After completion of the time, the alarm centre sets the
partition to active and the control unit shows which
partition is switched to active.
10.3 Deactivating a partition
The entry time starts when you open the entry door. An
intermittent beep is sounded during the entry time.
1. Enter your user code or hold your proximity code key at
the control unit. The display shows the partitions that you
can enter.
2. Press the corresponding partition button A, B, C or D
and then press .
The entry beep stops. The partition is now deactivated.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus Terxon SX - AZ4111 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus Terxon SX - AZ4111 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abus Terxon SX - AZ4111

Abus Terxon SX - AZ4111 Installation Guide - English, German, Dutch, Danish, French - 484 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info