Chapter III – Installation instructions – Option 95: Equipment
81
2.55.4 Option 95-4: False Settings
e.g. 1
Select this option to activate the alarm system
while the objects are occupied. You can choose
between the following:
1. Partitions to be activated.
2. Zones to be activated. Excluded zones are
shunted.
3. Release/lock all outputs (communication
outputs, bell, strobe, etc.)
The system deactivates the zones when the test
is completed.
2.55.5 Option 95-5: Default User 1
Select this option to reset user 001 (Manager
user) to the factory default code 1234 or 123400
(for a 6-digit code; see page 52).
2.55.6 Option 95-6: Network Errors
Select this option to view the number of data
transmission errors for each bus.
Transmission errors can be caused by: line faults,
bad wiring, frequency interference, voltage faults,
grounding faults, connection of cables of different
buses, and connection of cables of bells and
buses.
Important
You can reset the error counter to 0 by pressing
0. If you wish, you can use this option again
after a certain time to count the number of bus
errors in this period.
N
etwork 1 0003
Network 2 0254
Last error 2, 01
Equipment 6
Network Errors
[ENT] to DEFAULT
user code 1.
Equipment 5
Default User 1
Exit For Prtns:-
Prtn : 1**.....
Press ENT To Set
All outputs will
remain active
Prtns Set :-
Prtn : 1**.....
Select Zones
0002 Disarmed
TESTING COMPLETE
[ESC] to quit.
False set Prtns:
Prtn > ***.....
False set Prtns:
Prtn > 1**.....
Equipment 4
False Settings
Select Zones
0001 Disarmed
87


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus Terxon LX - AZ4200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus Terxon LX - AZ4200 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abus Terxon LX - AZ4200

Abus Terxon LX - AZ4200 User Manual - English - 16 pages

Abus Terxon LX - AZ4200 Installation Guide - German - 31 pages

Abus Terxon LX - AZ4200 User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info