75
Event Description
CNFG CHANGE ### Configuration of user ### changed
CNFG CHANGE #### Configuration of user #### changed
CODE ## Code of user ## entered
CODE ### Code of user ### entered
CODE #### Code of user #### entered
CODE LOCK # OFF Code lock # off
CODE LOCK # ON Code lock # on
CODE LOCKED ## User number ## tried to enter user code while locked.
CODE LOCKED ### User number ### tried to enter user code while locked.
CODE LOCKED #### User number #### tried to enter user code while locked.
CODE TAMPER Operating panel locked for 5 min due to invalid user code entry
COMMS FAILED Integrated modem could not connect to emergency command centre
COMMS TEST CALL Test call started
CONFIG CHANGE ## User configuration ## changed
DATE CHANGED AT System date changed on …
DATE CHANGED TO System date changed to …
DEFAULT USER User code 01 (administrator) to default
DEFAULT USER ## Not used
DEFAULT USER ### Not used
DEFAULT USER #### Not used
DEFERRED SET:- Delayed activation of partitions
DL DISCONNECT FL) Downloader disconnected with an error
DL DISCONNECT OK Downloader disconnected
DURESS CODE ## Duress alarm user ##
DURESS CODE ### Duress alarm user ###
DURESS CODE #### Duress alarm user ####
ENG HW DEFAULTED Factory reset of alarm centre
ENGINEER ARRIVES Engineer has logged into the system.
ENGINEER DEPARTS Engineer has logged out of the system.
ENTRY TIME-OUT:- Entry delay in partition expired
ENTRY ZONE #### Entry delay of zone #### started.
EXIT CANCELLED:- Exit delay for partition … cancelled.
EXIT STARTED:- Exit delay for partition … started.
EXT LINE FAULT Not used
EXT LINE RESTORE Not used
FACTORY RESTART Factory settings loaded
FIRE ALARM #### Fire alarm in zone ####
FIRE PARTITIONS:- Fire alarm in partition
FIRE RESET:- Fire alarm reset
FIRST KNOCK #### First activation of zone number #### (zones with the double confirmation
attribute)
FROM REMOTE #,## Not used
HI-SECURITY SET: Activation of partitions with high security
KEYPAD PANIC ### Panic alarm triggered on operating panel ### (keys 1 and 3 pressed)
KEYSWITCH ### Keyswitch zone #### activated
LOCAL ON LINE Local connection with downloader
LOCAL SERV CALL Local connection with downloader
LOCAL SERV END Not used
LOCKSET #### ON Keyswitch zone #### activated
LOCKSET #### OFF Keyswitch zone #### deactivated
LOCKSET PARTITION
ON
Key for partition released
MAIN POWER ON Mains power on in the alarm centre
MAINS POWER OFF Mains power off in the alarm centre
MASK FLT S #### Zone #### masked during activation
MASK FLT U #### Zone #### masked during deactivation
MASK TMP S #### Masking zone #### masked during activation
MASK TMP U #### Masking zone #### masked during activation
81


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus Terxon LX - AZ4200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus Terxon LX - AZ4200 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abus Terxon LX - AZ4200

Abus Terxon LX - AZ4200 User Manual - English - 16 pages

Abus Terxon LX - AZ4200 Installation Guide - German - 31 pages

Abus Terxon LX - AZ4200 User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info