44
Connect the inputs with the accessory module. Input 1 is used
for connecting the alarm contact for detectors. Alarm input 2 is
used for connecting the tamper line for detectors.
Set dip switches 5, 6 and 7 according to the input connection and
then close the housing on the accessory module.
Program the outputs in your wireless alarm system (see the
corresponding instructions).
6.3.4 Wireless siren module
Function 4 / LED 4 (only in combination with the Secvest)
When used as a wireless siren module, the accessory module is used
to trigger an external signalling device. This function can only be used
if the accessory module is combined with the wireless alarm system.
The signalling device is connected to the accessory module with a
six-pin cable (supplied with the signalling device).
To use the accessory module as a wireless siren module, proceed
as follows:
1. In the main programming menu, select item 7 (Function). LED 7
lights up.
Confirm by pressing SET.
In the submenu of item 7 (Function), select function 4 with the
SELECT button. LED 4 lights up.
Confirm by pressing SET.
LED 7 lights up again.
Set dip switch 3 of the accessory module to ON.
Exit the programming mode by pressing ESC/DEL.
Only the power supply LED lights up/flashes and the fault LED
lights up. The accessory module beeps at short intervals.
Close both tamper contacts of the WAM and wait until it emits
a double tone.
2. On the wireless alarm system, select Add Other
Devices/Wireless Accessory Module” and follow the installation
instructions for the alarm system. When prompted, trigger the
tamper contact of the accessory module and wait until the
wireless alarm system receives the signal from the accessory
module.
The accessory module is now trained as a wireless siren module.
No further programming is required.
Connect the cable of the siren to the RJ12 plug on the accessory
module. Alternatively, follow the instructions below on connecting
conventional sirens.
Note: When the siren is connected via the RJ12 plug on the
accessory module, jumpers 1 and 2 must be plugged as
follows:
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus fumo50020 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus fumo50020 in the language / languages: English, German, Dutch, Danish, French, Italian as an attachment in your email.

The manual is 2,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info