38
- Repeat this process exactly to train other detectors.
- After training all detectors, exit the programming mode by
pressing ESC/DEL twice. Only the power supply LED lights
up and the fault LED lights up. The accessory module
beeps at short intervals.
Close both tamper contacts of the IP alarm module and
wait until it emits a double tone.
Note: A total of eight wireless components can be trained in the IP
alarm module. Channels 1 to 4 are connected to output 1 and
channels 4 to 8 to output 2.
Either detectors or arming components can be trained in channels
1 to 4. Only detectors can be trained in channels 5 to 8. As soon as
a detector has been trained in one of the channels 1 to 4, then no
other arming components can be trained on the remaining
channels from 1 to 4. As soon as an arming component has been
trained in one of the channels 1 to 4, then no other detectors can
be trained on the remaining channels from 1 to 4.
5.4 Deleting wireless components
Wireless detectors can be deleted individually from the IP alarm
module. Proceed as follows to delete wireless detectors from the
IP alarm module:
In the main programming menu, select item 2 (LED 2 lights up).
Confirm by pressing SET.
The LEDs show the state of the trained wireless detectors. If an
LED illuminates, this indicates that a wireless detector is trained for
this channel.
Press SELECT to switch between the channels.
To delete a wireless detector, select the corresponding channel
and then press ESC/DEL. Keep this button pressed until the IP
alarm module beeps twice.
LED 2 lights up to indicate that you are in step 2 of the
programming mode.
To delete another wireless detector, press SET again. The LED of
an occupied channel illuminates again.
After deleting the detectors, exit the programming mode by
pressing ESC/DEL.
Only the power supply LED lights up and the fault LED lights up.
The accessory module beeps at short intervals.
Close both tamper contacts of the IP alarm module and wait until it
emits a double tone.