677231
25
Zoom out
Zoom in
Previous page
1/32
Next page
25 (32)
2
6
1
4 5
3
Programming the Scanning Method
Two scanning methods are available: Public scanning and Channel set scanning.
Public Scanning (PC)
The scanning on the lift indicator is controlled in this method by any freely
chosen GewaLink channel between 00-61 and 63-127. Any channel can be used
when transmitting.
Channel set scanning (DC)
The scanning of the lift indicator is controlled in this method by one set
GewaLink channel 00-61 and 63-127.
Proceed as follows to set the scanning method:
1. Enter programming mode if this has not been done, see specific section.
P
is
now shown on the display.
2. Direct the transmitter towards the lift indicator and press
0
3
.
P
C
or
D
C
is now shown on the display.
3. Select PC or DC using button
1
(step upwards) and
button
4
(step downwards).
4. Press
*
when the correct setting has been selected.
5. If DC has been selected, proceed and select GewaLink
channel. Select a channel between 00-61, 63-127. Write
channel 1 as 001 and channel 32 as 032 etc.
O
K
is shown on the display
when the channel has been entered.
6. Complete the programming by pressing
0
0
or proceed and program other
functions.
Quick Guide
Programming a scanning method:
0
3
,
select
P
C
or
D
C
,
confirm with
*
. If
DC is selected, select channel.
Default value = Public scanning.
Programming Direct Control by GewaLink channel
With direct control it is possible to go directly to a floor without using scanning.
This can be used by a person who always goes to the same floor and when there
is no need for scanning. Scanning can still be used as usual. To program this
function “Channel set scanning” must be selected in the previous section.
Proceed as follows to program Direct control of a floor:
1. Enter programming mode if this has not been made, see specific section.
P
is
now shown on the display.
2. Direct the transmitter towards the lift indicator and press
0
7
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abilia 808620 - IR-LIFT MAXI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abilia 808620 - IR-LIFT MAXI in the language / languages: English, Swedish as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info