541310
110
Zoom out
Zoom in
Previous page
1/177
Next page
6.47 Multi-sequencer 110
The numbered gate buttons control the gate output signal. The output will generate a square
pulse of 1/8 of a quarter note with an amplitude of 1 Volt for each active gate buttons. To hear a
step, the gate button must be clicked (green light on). The loop buttons are used to set the length
of the Pattern from 1 to 16 steps.
Song Mode
The sequencer can play patterns individually or in a programmed order using a song. The song
mode is activated by placing the mode selector to song. The sequencer can hold 8 songs. A song
can hold up to 1000 events. The sequencer will loop each time a song ends. To make the sequencer
stop at the end of a song, the once button must be clicked.
Five parameters are associated with each pattern on the square display: pattern, primary loop
point (L), primary loop times (PRI), secondary loop times (SEC) and play mode (MODE). Each of
the parameters on the window is adjusted by clicking-holding and dragging. The keyboard arrows
can also be used once a parameter has been selected. The pattern parameter determines the pattern
to be played for a given event, from A1 to D8.The primary loop is a group of events that will be
played a number of times equal to the value of the primary loop times (PRI) parameter. In order
to program a primary loop of events, the beginning and the end of the loop must be selected by
the primary loop point parameter. This parameter has 3 values: none (-), start (S) and end (E).
Selecting start sets the return point of the loop to a given event and activates the primary loop times
parameter, which can be set from 1 to 99. Selecting end (E) in any subsequent event will make the
sequencer return to the start event until the number of loops is reached. Note that placing a primary
loop inside another one will not produce the desired effect. The secondary loop times parameter
sets the number of times an event will be played before switching to the next. It can be set from 1
to 99. The play mode parameter change the play mode of the sequencer. The sequencer will stay in
the selected play mode for the next events. In order to make song programming easier, use of the
play from position (PFP) button is useful. It allows to start the song from a selected event. When
clicked, the first event in the edit window will be remembered as the first and return event of the
song.
Editing a song
The song info window at the top of the event window displays the event currently being played or
selected with the wheel located at the right of the event window. Events can be removed from a
song by clicking on the “-” button on the right of the song info window. Pressing on the “+” button
inserts a new event after the event currently selected.
Note: see also Control Voltage Sequencer, Control Voltage Sequencer with Songs, Single
Gate Sequencer, Single Gate Sequencer with Songs, Dual Gate Sequencer and Dual Gate
Sequencer with Songs.
110


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AAS Tassman 4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AAS Tassman 4 in the language / languages: English as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info