Instruction manual TWI 35-130 G/TWI 45-190 G 47
Instruction manual - TWI 35-130 G/TWI 45-190 G 47
Pannes s’afchant sur la commande
Light pulses Cause Solution Remark
3 (SL3)
Three ignition
attempts without
success
No gas supply 1. Open the mains gas supply valve and/or the manual gas valve
for the gas control.
2. Check the pre-pressure on the gas control.
3. If necessary, restore the gas supply.
Contact your installation engineer for restoring the gas supply.
Air in the gas pipe Bleed the gas pipe. Contact your installation engineer for replacing the required parts.
No gas supply to
burner
1. Check if the gas valve switches.
2. Replace the gas control if necessary.
Error in the hot
surface igniter circuit
1. Check if the hot surface igniter has been properly connected.
See (12.2 “Electrical circuit diagram”).
2. Check the cabling of the hot surface igniter.
3. Check the voltage over the hot surface igniter. This should be
115 VAC.
4. Measure the resistance over the hot surface igniter. This
should be between 45 and 400 Ohms.
5. Replace the hot surface igniter if necessary.
Contact the installation engineer in case of reoccurring errors.
Contact the installation engineer for replacing the required parts.
Phase and Zero
incorrectly connected
Correctly connect the Phase and the Zero (3.9 “Electrical
connection”). The device is phase-sensitive.
Error in the ionisation
circuit
1. Check if the hot surface igniter has been properly connected.
See (12.2 “Electrical circuit diagram”).
2. Check the cabling of the hot surface igniter.
3. Check if the ground wire of the burner has been properly
connected.
4. Replace the hot surface igniter if necessary.
Supply voltage too low Check the supply voltage. This should be 230VAC (-15% +10%).
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith TWI 35-130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith TWI 35-130 in the language / languages: English as an attachment in your email.

The manual is 2,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith TWI 35-130

A.O. Smith TWI 35-130 User Manual - German - 64 pages

A.O. Smith TWI 35-130 Usermanual and installation guide - Dutch - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info