Start the appliance (see section 4.1).
The appliance will now run the heating cycle (see section 4.1.1).
Read the pressure from the meter at the moment when the appliance switches from
PRE PURGE to PRESSURE SWITCH. At this point, the appliance's display will show:
Check whether the measured value matches the value from the table (see section
12.1)
.
Note
If the message PRESSURE SWITCH does not appear, there is a fault. This must be
resolved first by a qualified service engineer.
Shut off the gas supply.
Disconnect the pressure gauge.
Put the two black caps back on the pressure switch.
Replace the covers.
7.9.6 Turn on the water heater
Refer to the procedure in the user part to Turn on the water heater (see section 4.1).
7.10 Decommisioning
To decommission the water heater:
Turn off the water heater (see section 7.10.1)
Drain the water heater
7.10.1 Turn off the water heater
Refer to the procedure in the user part to Turn off the water heater (see section 4.2) and
isolate the water heater from the mains power supply.
7.10.2 Draining
7.10.2.1 Draining unvented installations
Some service activities require the water heater to be drained. The procedure is as
follows:
Activate the MENU with [ ].
Position the cursor in front of OFF.
Confirm OFF with [ENTER].
Wait until the fan has stopped. The icon is then dimmed.
Caution
Failure to wait until the fan stops can cause damage to the water heater.
Switch the water heater OFF (position 0) using the control switch on the operator
interface.
Isolate the water heater from the power supply by setting the isolator between the
water heater and the mains power supply to position 0.
Shut off the gas supply (10).
Close the stop valve (11) in the hot water pipe.
Close the supply valve (4) in the cold water inlet (A).
8.
9.
10.
11.
n
12.
13.
14.
15.
1.
2.
1.
2.
3.
4.
c
5.
6.
7.
8.
9.
78 Installation, Maintenance and Service part
78


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 100 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 100

A.O. Smith SGS 100 User Manual - German - 128 pages

A.O. Smith SGS 100 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info