7.8.3 Optional electrical connections
Optionally, it is possible to:
Connect an isolating transformer (see section 7.8.3.1).
Connect a program-controlled pump (see section 7.8.3.2).
Connect an external ON mode switch (see section 7.8.3.3).
Connect an additional error signal (see section 7.8.3.4) to the water heater.
7.8.3.1 Isolating transformer
For more information about an isolating transformer, or to order an isolating transformer,
please contact A.O. Smith.
An isolating transformer should be used if there is a case of 'floating neutral'.
Note
The total power consumed by the appliance goes via the isolating transformer.
Refer to the fitting instructions provided with the isolating transformer. (Contact the
supplier for details of the correct isolating transformer.)
Connect the neutral (N), live (L) and earth (A) of the power cables to terminals 4
through 9 of the connection block according to the table (see section 7.8.1).
Fit the cables in the strain relief.
If you have no more connections to make:
Fit the cover on the terminal block.
Fit the covers onto the water heater.
Connect the power cable to the isolator.
7.8.3.2 Program-controlled pump
Note
The maximum power capacity for a pump regulated by the controller is 100W.
Connect neutral (N), live (L) and earth (A) to terminals 13, 14 and 15 as indicated in
the table (see section 7.8.1).
Fit the cable in the strain relief.
If you have no more connections to make:
Fit the cover on the terminal block.
Fit the covers onto the water heater.
7.8.3.3 External ON mode switch
External ON/OFF is an option for connecting an external ON/OFF switch. In the OFF
position, the programmed operating mode is active. In the ON position, the programmed
operating mode is overruled, and "ON mode" is active.
Connect leads (X3 and X4) to terminals 21 and 22 according to the table (see section
7.8.1)
.
Fit the cable in the strain relief.
If you have no more connections to make:
Fit the cover on the terminal block.
Fit the covers onto the water heater.
7.8.3.4 Additional error signal
The appliance has a relay terminal that is switched when an error is detected. This can be
used to signal errors, for example with a bulb. A 230V circuit can be powered directly.
Other voltages require a relay prescribed by the manufacturer.
Connect the phase cables (X1 and X2) to points 10 and 11 according to the
table
(see section 7.8.1)
. If required, connect earth (A) to terminal 12.
Fit the cable in the strain relief.
If you have no more connections to make:
Fit the cover on the terminal block.
Fit the covers onto the water heater.
n
1.
2.
3.
4.
-
-
5.
n
1.
2.
3.
-
-
1.
2.
3.
-
-
1.
2.
3.
-
-
0311753_SGS_28-120_II_UKUK_V2.0 , 2017-05-03 67
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 100 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 100

A.O. Smith SGS 100 User Manual - German - 128 pages

A.O. Smith SGS 100 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info