503238
50
Zoom out
Zoom in
Previous page
1/96
Next page
Status of the appliance
50 Instruction manual ADMR
8
gis
8.2.4
PROG
In this mode a preset week program is active, and the
appliance responds continually to demand within the
time periods set in the week program. There are two
distinct situations possible in this mode:
1. The current time falls within a set time period
of the week program.
The figure shows the display with the following
information:
- line one: the text
PROG
;
- line two: the time, the day and T
1
and T
net
alternately (2.3 "The appliance's heating
cycle");
- line three: the next scheduled switch-off time
and the water temperature T
set
of the active
period;
- line four: is empty, or depending on the
heating cycle (2.3 "The appliance's heating
cycle"), a text such as
HEAT DEMAND
.
2. The current time falls outside a set time period
of the week program.
The figure shows the display with the following
information:
- line one: the text
PROG
;
- line two: the time, the day and T
1
and T
net
alternately (2.3 "The appliance's heating
cycle");
- line three: the next scheduled switch-on
time;
- line four: displays the text
PERIOD ACTIVATED
.
In all modes, the temperature may at any moment
drop below the desired temperature. The appliance
then enters a heating cycle. This heating cycle is
identical (2.3 "The appliance's heating cycle")
for all
basic operating modes.
Note
Setting and if necessary programming of the basic
operating modes are described in the main
menu (11 "Main menu") chapter.
8.3 Error conditions
The figure shows an example of an error condition. If
the appliance enters this condition, the display will
show the following information:
line one: error code comprising a letter and two
digits, followed by the error description;
lines two to four: alternately, a brief explanation of
the error, and a brief action to resolve the error.
CautionThe displayed action to resolve the error
may only be performed by a service and
maintenance engineer.
There are various types of errors:
LOCK OUT ERRORS
When the cause has been removed, these errors
require a reset with the button before the
appliance can resume operation.
BLOCKING ERRORS
These errors disappear automatically once the
cause of the error has been removed, after which
the appliance resumes operation by itself.
The display does not show what type of error has been
detected. A comprehensive overview of the errors is
provided elsewhere in the
manual (13 "Troubleshooting")
.
If, as end-user, you find the appliance in an error
condition, you may attempt to restart the appliance by
pressing the button
However, if the error returns or occurs several times in
a short time you must contact your service and
maintenance engineer.
8.4 Service condition
The figure shows the message
SERVICE REQUIRED
.Should this message appear,
then the appliance is in need of a service and
maintenance inspection. In that case, contact your
service and maintenance engineer.
Note
The message
SERVICE REQUIRED
is based on
the number of expired burning hours and the preset
service interval. Should the service interval have been
incorrectly selected, contact the service and
maintenance engineer for instructions on how to
adjust this. Information on the maintenance frequency
is provided elsewhere in the
manual (14 "Maintenance frequency").
PROG
10:00 Monday 76ÉC
MO 11:15 Tset 75ÉC
PROG
12:00 Monday 76ÉC
MO 11:15
PERIOD ACTIVATED
S04: SENSOR ERROR
CHECK
SENSOR OR DUMMY
!!! WARNING !!!
MAX. BURNING HOURS:
SERVICE REQUIRED
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith ADMR135 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith ADMR135 in the language / languages: English as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith ADMR135

A.O. Smith ADMR135 User Manual - Dutch - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info